Advertisement

B0063191 / 1.3
6.6.5
CSP file for CC-Link
The CSP file contains the specific configuration data of the device. The data must be known to the
controller.
The manufacturers of the controller supply the tools for the integration of the CSP file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the controller.
The CSP file is supplied on a CD or can be downloaded from the Roland homepage.
Three „occupied Stations" with 36 Byte are used. 12 Byte are Bit Data Area and 24 Byte Word Data
Area.
Link Input (Roland R1000 => PLC)
W0 W1 W2 W3 W4 W5
Bit Data area
word 0 to 4 (Byte 0-9)
not used
Link Output (PLC => Roland R1000)
W0 W1 W2 W3 W4 W5
Bit Data area
word 0 to 4 (Byte 0-9)
not used
*1) Remote Ready: after Roland R1000 is ready for Data exchange the signal Remote READY is set. If Remote READY is
off the Data in the user area are not valid.
By pressing the key "
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
W6
W7
System area
Word Data area
word 5
word 0 to 3
Bit 3 =
Roland L20
Remote
Parameter channel
Ready *1)
(see Chapter 6.4)
W6
W7
System area
Word Data area
word 5
word 0 to 3
not used
Roland L20
Parameter channel
(see Chapter 6.4)
" status indicators are shown on the display.
Status Indicators
Nr.
LED
State
LED 1 RUN
Green On
Green Off
LED 2 ERRL
Red On
Red Off
LED 3 RDLED
Green On
Green Off
LED 4 SDLED
Green On
Green Off
Manual
W8
W9
W10 W11
W12 W13 W14
Word Data area
word 4 to 11
Roland L20 Process channel (see Chapter 6.3)
W8
W9
W10 W11
W12 W13 W14
Word Data area
word 4 to 11
Roland L20 Process channel (see Chapter 6.4)
Description
Normal operation
Network non-participating or timeout status
No power on the module
CRC Error detected
Illegal station number or illegal baudrate detected
Normal Operation
No power on the module
Data being received
No data reception
No power on the module
Data being transferred
No data transmission
No power on the module
Communication with the PLC
W15 W16 W17
W15 W16 W17
63