Communication with the PLC
6.5.4
External continuous measurement / External special via external inputs
Fig. 27: Timing diagram for external continuous measurement / external special via external inputs
1)
At "function error" the "function result" not set mandatory.
2)
The measuring time depends on the time set for averaging.
*
The status of the 0-,1-,2-sheet and warning outputs are updated via the Fieldbus (BOUT) with a refresh rate of 6 ms.
The refresh rate via I/O Outputs is 1 ms.
58
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Note
The output "function result" is set with the arrival of the first measured
value and remains set.
Note
In the "extern special" measurement mode the highest measured value
will be displayed and held at the outputs until a new measurement is
started.