Program Parameters - Roland R1000 Series Manual

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
7.7

Program parameters

The program parameters contain the information required for the various measurement programs.
For accessing the program parameters, select the mode "configuration program parameter" and
confirm with ENTER.
Program parameter 1: Selecting the measuring program to be configured.
Program Parameter: 1
Program Number
Fig. 38: Selecting the program to be configured
At this point select the measuring program (1-255) that needs to be configured. All following
adjustments apply to the selected program.
Program parameter 2:
For L20-XX-S not available.
For L20-3-XX-S:
Programmparameter: 2
active meas.channel
Fig. 39: Selecting the active measuring channel
At this point select the active measuring channel used during the measuring operation.
Possible choices are: 1 / 2 / 3 / 1+2 / 1+3 / 2+3 / 1+2+3
(in function of selected measuring channels in the substructure „system parameter", item 11)
Program parameter 3: Specifying the nominal thickness and material of the sheet to be
measured (in mm/inch).
Program Parameter: 3
nominal thickness
0.900 mm
Fig. 40: Adjusting the nominal thickness
The minimum and maximum adjustable nominal dimension (thickness of the sheet) is depending
on sensor type:
-
LAAS10 / LAAS10+:
-
LAAS40 / LAAS40+:
-
LAAS200 / LAAS200+:
Program parameter 4: not available
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
1
1
from 0.1 mm to 5 mm / from 0.004 inch to 0.196 inch
from 0.3 mm to 15 mm / from 0.012 inch to 0.59 inch
from 1.5 mm to 99 mm / from 0.06 inch to 3.93 inch
Manual
Start-up
75