Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
6.6.7
Device Description file for EtherCAT
The Device Description file contains the specific configuration data of the device. The data must be
known to the controller. The manufacturers of the controller supply the tools for the integration of
the Device Description file into the network. Roland Electronic does not supply such tools, because
they have to be compatible with the interface design of the controller.
The Device Description file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Note
24 Bytes I/O must be set.
" status indicators are shown on the display.
Nr.
LED
LED 1 Link/Activity 1
LED 2 RUN
LED 3 ERR
LED 4 Link/Activity 2
Manual
Status Indicators
State
Description
Off
No link sensed on Ethernet port 1
Green
Link sensed on Ethernet port 1
Green flickering
Exchanging packets on Ethernet port 1
Off
The device is in INIT state
Green, blinking
The device is in PRE-OPERATIONAL state
Green, single
The device is in SAFE-OPERATIONAL state
flash
Green
The device is in OPERATIONAL state
Off
EtherCAT is in communication condition
Red, flashing
General configuration error
Red single flash
Slave device application has changed the EtherCAT
state autonomously: Parameter „Change" in the AL
status register is set to 01 (change/error).
Red double
Sync manager watchdog timeout
flash
Red
Application watchdog timeout
Off
No link sensed on Ethernet port 2
Green
Link sensed on Ethernet port 2
Green, flashing
Exchanging packets on Ethernet port 2
Communication with the PLC