Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
6.3.9
Dummy function
BIN8.2 / BIN8.3 / BIN11.3/ ...
BOUT8.0
Function result
BOUT8.2
Function fault
BOUT8.3
Fig. 23: Timing diagram for Dummy function
1)
In case of "Function fault" "Function result" is not necessarily set.
6.3.10 Reset Function fault
Fig. 24: Timing diagram for reset function fault
1)
In case of "Function fault" "Function result" is not necessarily set.
BOUT8.3 is not reset if a critical systems fault is present. Examples are memory fault, power
failure, or low voltage. Critical faults cannot be reset via the process channel. Theses faults must
be reset via keyboard.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
1)
Ready
Note
The measured timing periods were determined with12 Mbit/s Profibus.
These timing periods can vary with different transmission rates and bus
systems. The cycle time of the PLC has not been taken into account.
Note
The measured timing periods were determined with12 Mbit/s Profibus.
These timing periods can vary with different transmission rates and bus
systems. The cycle time of the PLC has not been taken into account.
Manual
"1" if fault
0V if fault
< 15 ms
Communication with the PLC
< 15 ms
47