Roland R1000 Series Manual page 39

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
Bytes 15 to 17:
The following signals are used in the L20-3-XX-S unit version only.
Inputs (PLC  L20)
Byte.Bit
Meaning
BIN15.0
System test Measuring channel 2
BIN15.1
---
BIN15.2
Calibration Measuring channel
BIN15.3
Dummy function
BIN15.4
---
BIN15.5
---
BIN15.6
---
BIN15.7
---
BIN16.0
---
BIN16.1
---
BIN16.2
---
BIN16.3
---
BIN16.4
---
BIN16.5
---
BIN16.6
---
BIN16.7
---
BIN17.0
---
BIN17.1
---
BIN17.2
---
BIN17.3
Dummy function
BIN17.4
Dummy function
BIN17.5
---
BIN17.6
---
BIN17.7
Range (only L20-3-XX-S)
2)
For the outputs „0V active" or „24V active" is selectable in the device configuration. This has also effect to the I/O
outputs.
3)
The „Dummy Function" sets only the output „Function result". This was implemented due to reasons of compatibility.
4)
The output of the measured value is done in dependency of the chosen unit of measure at the fieldbus output and
the type of sensor:
Measuring unit
(mm or inch)
mm
inch
5)
This function is implemented only in L20-3-XX-S (L20-XX-S in preparation).
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
5)
2
3)
3)
3)
Sensor type
LAAS10 (in preparation)
-3
0...20000 x 10
mm
(micrometer)
-4
0...7874 x 10
inch
(1/10000 inch)
Manual
Outputs (L20  PLC)
Byte.Bit
Meaning
BOUT15.0
Always „0" (Low)
BOUT15.1
Always
BOUT15.2
---
BOUT15.3
---
BOUT15.4
Warning
BOUT15.5
0-sheet
BOUT15.6
1-sheet
BOUT15.7
2-sheet
BOUT16.0
BOUT16.1
BOUT16.2
BOUT16.3
High Byte measuring value
BOUT16.4
BOUT16.5
BOUT16.6
BOUT16.7
BOUT17.0
BOUT17.1
BOUT17.2
BOUT17.3
Low Byte measuring value
BOUT17.4
BOUT17.5
BOUT17.6
BOUT17.7
Sensor type
LAAS40
LAAS200 (in preparation)
-3
0...40000 x 10
mm
(micrometer)
-4
0...15748 x 10
inch
(1/10000 inch)
Communication with the PLC
„1"(High)
2)
2)
Measuring channel
2
2)
Measuring channel
2
2)
Measuring channel
2
4)
Measuring channel
4)
Measuring channel
Sensor type
Example at
LAAS40
-2
0...20000 x 10
mm
1000 = 1 mm
(10 micrometer)
-3
0...7874 x 10
inch
1000 = 0.1 inch
(1/1000 inch)
2
2
39