Roland R1000 Series Manual page 40

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Communication with the PLC
Bytes 18 to 20:
The following signals are used in the L20-3-XX-S unit version only.
Inputs (PLC  L20)
Byte.Bit
Meaning
BIN18.0
System test Measuring channel 3
BIN18.1
---
BIN18.2
Calibration Measuring channel
BIN18.3
Dummy function
BIN18.4
---
BIN18.5
---
BIN18.6
---
BIN18.7
---
BIN19.0
---
BIN19.1
---
BIN19.2
---
BIN19.3
---
BIN19.4
---
BIN19.5
---
BIN19.6
---
BIN19.7
---
BIN20.0
---
BIN20.1
---
BIN20.2
---
BIN20.3
Dummy function
BIN20.4
Dummy function
BIN20.5
---
BIN20.6
---
BIN20.7
Range (only L20-3-XX-S)
2)
For the outputs „0V active" or „24V active" is selectable in the device configuration. This has also effect to the I/O
outputs.
3)
The „Dummy Function" sets the output „Function result" only. This was implemented due to reasons of compatibility.
4)
The output of the measured value is done in dependency of the chosen unit of measure at the fieldbus output and
the type of sensor:
Measuring unit
(mm or inch)
mm
inch
5)
This function is implemented only in L20-3-XX-S (L20-XX-S in preparation).
Bytes 21 to 23:
Bytes 21 to 23 are reserved for future extensions.
40
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
5)
3
3)
3)
3)
Sensor type
LAAS10 (in preparation)
-3
0...20000 x 10
mm
(micrometer)
-4
0...7874 x 10
inch
(1/10000 inch)
Note
In the following timing diagrams all outputs and inputs via the bus are
designated as BOUT and BIN, in contrast, the opto coupler interface
uses OUT or IN.
Manual
Outputs (L20  PLC)
Byte.Bit
Meaning
BOUT18.0
Always „0" (Low)
BOUT18.1
Always
BOUT18.2
---
BOUT18.3
---
BOUT18.4
Warning
BOUT18.5
0-sheet
BOUT18.6
1-sheet
BOUT18.7
2-sheet
BOUT19.0
BOUT19.1
BOUT19.2
BOUT19.3
High Byte measuring value
Measuring channel 3
BOUT19.4
BOUT19.5
BOUT19.6
BOUT19.7
BOUT20.0
BOUT20.1
BOUT20.2
BOUT20.3
Low Byte measuring value
Measuring channel 3
BOUT20.4
BOUT20.5
BOUT20.6
BOUT20.7
Sensor type
LAAS40
LAAS200 (in preparation)
-3
0...40000 x 10
mm
(micrometer)
-4
0...15748 x 10
inch
(1/10000 inch)
B0063191 / 1.3
„1"(High)
2)
2)
Measuring channel 3
2)
Measuring channel 3
2)
Measuring channel 3
4)
4)
Sensor type
Example at
LAAS40
-2
0...20000 x 10
mm
1000 = 1 mm
(10 micrometer)
-3
0...7874 x 10
inch
1000 = 0.1 inch
(1/1000 inch)