Switching Over Sls Levels - Siemens Sinamics G120 Function Manual

Safety integrated
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

Operation
6.6 Safely Limited Speed (SLS)
6.6.3

Switching over SLS levels

Overview
When SLS is active, you can switch between four different speed levels via PROFIsafe. The
drive response when switching over to a lower SLS level depends on whether you have
selected SLS with or without braking ramp monitoring.
The inverter monitors the motor as it brakes using
the SBR (Safe Brake Ramp) function.
Switching over SLS levels is only possible via PROFIsafe with control word 1.
The inverter signals the active SLS level via PROFIsafe to the higher-level control.
260
With braking ramp monitoring
Control word 1 and status word 1 (extended functions) (Page 53)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Without braking ramp monitoring
After an adjustable time, the inverter switches the
SLS monitoring from the higher SLS level to the
lower SLS level.
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD