Siemens Sinamics G120 Function Manual page 255

Safety integrated
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

Selecting SLS at low motor speeds
If the motor speed when selecting SLS is less than the SLS limit, then the drive responds as
follows:
The inverter monitors the speed after the "delay
time for the braking ramp".
Deselect SLS
If the higher-level controller deselects SLS, then the inverter deactivates limiting and
monitoring.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
With braking ramp monitoring
6.6 Safely Limited Speed (SLS)
Without braking ramp monitoring
The inverter monitors the load speed after an ad‐
justable delay time has expired.
Operation