System properties

8.3 Certification

8.3
Certification
Certifications
The safety functions fulfill the following requirements:
"STO via Power Module terminals"
Control via terminals STO_A and STO_B in the SINAMICS
G120 PM240‑2 or PM240P‑2 Power Module, FSD ... FSF
● Category 3 and Performance Level (PL) e according to
EN ISO 13849‑1: 2008
● Safety integrity level 3 (SIL 3) to IEC 61508: 2010
● EC Declaration of Conformity
EC type-examination certificate and manufacturer declaration
The safety functions integrated in the drive are certified by a test institute for each of the
firmware versions that have been released. With the EC type-examination certificate, the test
institute confirms that the safety functions comply with the requirements as laid down in
EN ISO 13849-1 and IEC 61508.
We provide a manufacturer's declaration for the transition period from releasing a firmware
version up to the test institute issuing an EC type-examination certificate. The manufacturer
declaration confirms that the safety functions are in conformance with the appropriate
standards.
Procedure
Proceed as follows, to load the certificates relevant for Safety Integrated from the Internet:
1. Open the following page in the Internet:
Certificates (http://support.automation.siemens.com/WW/view/en/36426537/134200)
2. Filter according to Certificate type "Functional safety/machine safety".
3. Select the certificate according to the inverter article number.
– There is an EC type-examination certificate and a manufacturer declaration for each
– Each certificate includes lists with the associated firmware and hardware.
370
inverter family.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
All other safety functions of the SINAMICS G110M, G120,
G120C, G120D and SIMATIC ET 200pro FC‑2 inverters
● Category 3 and Performance Level (PL) d according to
EN ISO 13849‑1: 2008
● Safety integrity level 2 (SIL 2) to IEC 61508: 2010
● EC declaration of conformity
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD