Tr-Ln-Bd (Trunk Line Board) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

TR-LN-BD (Trunk Line Board)

TR-LN-BD (Trunk Line
Board)
The TN797 Analog Trunk and Line circuit pack provides 8 ports, any of which may
be administered as one of the following:
Table 10-662. TN797 Analog Trunk and Line circuit pack – port administration
Function
Central Office trunk
(CO)
CAMA/E911 trunk
Direct Inward Dialing
(DID) trunk
Analog Line
on-or-off premises
In the U.S., Canada, and like countries, all CO trunk ports of TN797 Analog Trunk
and Line circuit pack should be administered as ground start (GS) trunks rather
than as loop start trunks, because GS signaling provides disconnect supervision,
and loop start does not. If for some reason, a port on the TN797 must be
administered as loop start, it must be administered as one-way only – either
incoming or outgoing – not only at the DEFINITY switch, but also at the CO
switch. This is necessary to avoid collisions, i.e., "glare", and other highly
undesirable conditions.
The TN797 Analog Trunk and Line circuit pack does not support Neon Lamp
Message Waiting Indication (MWI). No maintenance of the terminal connected to
the Neon Analog Line circuit pack is performed.
For circuit pack problems, refer to the "XXX-BD (common port circuit pack)"
maintenance documentation.
555-233-123
Group Type
Trunk Type
co
loop start
fx
ground start
wats
cama
wink start
did
immed start
n/a
LED MWI
with/
n/a
without MWI
Issue 4 May 2002
10-1819