TIE-TRK (Tie Trunk)

TIE-TRK (Tie Trunk)
MO Name (in
Alarm Log)
2
TIE-TRK
TIE-TRK
TIE-TRK
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit port
number (for example, 01).
2
Not relevant to the TN497 circuit pack.
3
A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by
the set options command and that at least 75 percent of the trunks in this trunk group
are alarmed. (This is not relevant to the TN497 circuit pack.
NOTE:
If ATMS testing is enabled, check the error log for ATMS Errors #3840 and
#3841. If the error log indicates that measurements exceeded acceptable
thresholds, and if no other trouble is found with the test trunk command,
run the ATMS test call with the test analog-testcall port PCCSSpp full
command.
The following circuit packs are covered by this section of TIE-TRK (Tie Trunk):
TN760 series
TN437 [G3iV2-386]
TN439 [G3iV2-386]
TN458 [G3iV2-386]
TN497 [G3iV2-386]
TN2140 [G3iV2-386]
The Tie Trunk circuit pack fits into a port slot and contains four trunk circuits (see
Figure 10-97 on page
an analog tie trunk going to another PBX across one-way dedicated circuits
(except for the TN497 circuit pack) or across two-way dedicated circuits. Except
for the TN439 and TN497 circuit packs, each tie trunk has a 4-wire audio
connection and may have two signaling leads (E and M). Each tie trunk for the
TN439 and TN497 circuit packs has 2-wire audio connection/signal leads (A and
B).
In G3iV1.1-286 or G3iV2-386, a tie trunk port can also be administered as an
access endpoint, which is a non-signaling channel with a voice-grade data
bandwidth.
555-233-123
Alarm
Level
Initial Command to Run
3
MAJOR
test port PCSSpp l
MINOR
test port PCSSpp l
WARNING
test port PCSSpp sh
10-1756). Each of these circuits interface a digital PBX to
Full Name
1
of MO
Tie Trunk
Tie Trunk
Tie Trunk
Issue 4 May 2002