NE53 History
Table I-1
Transmitter software change history continued
Software
Date
version
09/2009
6.x
262
Changes to software
Software expansion
Frequency output configurable as discrete output on Series 1000
transmitters
Discrete output assignable as flow switch on Series 1000 transmitters
Display Variable 1 optionally fixed to process variable assigned to
primary mA output
Frequency output scaling method and related parameters
configurable from display
For enhanced density and petroeum measurement process variables,
display cycles among variable name, current value and unit, and
reference temperature
Software adjustment
The following combinations are not allowed:
• mA Output Fault Action=None and Digital Communications Fault
Action=NAN
• Frequency Output Fault Action =None and Digital Communications
Fault Action=NAN
Display variables set to a volume process variable automatically
switch between liquid and GSV, according to current setting of Volume
Flow Type
Feature addition
Configurable hysteresis for flow switch
Field Verification Zero added to support Weights & Measures
application
Transmitter firmware checksum and core processor firmware
checksum assignable as display variables and viewable in ProLink II
Micro Motion Series 1000 and Series 2000 Transmitters
Operating
instructions
20001715 BA