(4) Fasten the black cover with the 8 bolts. (M6 x 16).
Left Side
(5) Connect the connectors.
(6) Close the operation panel and install the front door.
Front Door
Side Door
WARNING!
Hold the cover with your hand and keep your safety during retightening.
Knob
38
[Fastening Torque]
4.3~6.4 N・m (44~65 kgf・cm)
Cover (back)
Bolt (M6 x 16)
Connect the connector.
1) Lift the front door up and engage the
hinges again.
2) Retighten the operation panel with the
two knobs.
3) Close the front door until an audible
"click" is heard.
Operation Panel