Rewire The Side Door - Shindaiwa DGK70F Service Manual

Diesel engine generator
Table of Contents

Advertisement

4. Rewire the side door

(1) Lift the side door up and engage the two hinges.
Left Side
(2) Tighten the stopper with the bolt. (M8 x 35)
Left Side
(3) Torque the 6 terminals and 1 terminal with the nuts. (M12 & M8).
Blue
Red
Green
Black
Blue
White
[Fastening Torque]
11~16 N・m (112~163 kgf・cm)
Red
Torque the terminals for #L1 (red), #L2
(white), #L3 (blue), #U (red) and #W
(blue) with the 2 black wires and nut.
Torque the grounding wire (green) and
the nut.
(M8) 1 location
(M12) 6 locations
[Fastening Torque]
(M8) :11.0~16.0 N・m (112~163 kgf・cm)
(M12):34.4~44.1 N・m (351~449 kgf・cm)