Energy Save Mode - Oki MC160MFP Maintenance Manual

Diode color all in one printer
Hide thumbs Also See for MC160MFP:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
13.3.13
TWAIN TIMEOUT
14.3.13
TWAIN TIMEOUT
Function
• To specify the time for TWAIN time out.
Use
• The default setting is 6 min.
Setting/
procedure
2min / 4min / "6min" / 8min / 10min / 12min / 14min / 16min / 18min
13.3.14
14.3.14

ENERGY SAVE MODE

ENERGY SAVE MODE
Function
• Set weather to activate Energy Save mode when print job receiving or panel operation
have not been made for a given period.
Use
• The default setting is ON.
Setting/
procedure
13.3.15
ENABLE WARNING
14.3.15
ENABLE WARNING
A. T/C LOW
Function
• Specifies whether or not a warning appears when the toner is about to run out.
Use
• The default setting is ON.
Setting/
procedure
B. I/C LOW
Function
• Specifies whether or not a warning appears when the print unit is about to reach the end
of its service life.
Use
• The default setting is ON.
Setting/
procedure
13.4 ADJUST
14.4 ADJUST
• Different adjust items are applicable and the corresponding adjust values become valid
according to the specific sub-function of the main function (Copy, Fax, Twain, or
NetScan) as detailed below.
Copy
Adjust item
CIS
CIS MAIN ZOOM
CIS SUB ZOOM
CIS MAIN REGIST
CIS SUB REGIST
ADF SUB ZOOM
X
ADF MAIN REG
X
ADF SUB REG
X
44292401TH Rev.1
"ON" / OFF
"ON" / OFF
"ON" / OFF
Function
Fax
Twain
Scan
ADF
CIS
ADF
CIS
ADF
CIS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
14.4.1
CIS MAIN ZOOM
13.4.1
CIS MAIN ZOOM
• To adjust for variations in the accuracy of IR parts and their mounting accuracy by
Function
varying the scanning zoom ratio in the main scanning direction.
• When the MFP board has been replaced.
• When the scanner unit has been replaced.
Use
NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new
setting value is necessary.
• Adjust the width of D in the copy of the test pattern1 so that the following specification
is met.
• 100 ± 0.5% (Zoom Ratio = Full Size:100%)
Adjustment
Specification
• The default setting is 0%.
Adjustment
• -2.0% ~ "0%" ~ +2.0%
Range
• Step: 0.2%
1. Print the test pattern1.
See P.131
2. Enter the [ADJUST] menu in the service mode.
3. Select [CIS MAIN ZOOM] of [ADJUST] and press the Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
Setting/
• Use A4 or Letter paper loaded into tray1 to make the test copy.
Procedure
5. Check that the width of D in the copy of the test pattern1 meets the specification.
Calculation: (1 - Width of D in the document
If the width of D is out of specification, adjust it according to the following procedure.
6. Press the Select key.
7. Using the
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check
it.
• If the width of D in the test pattern is longer than the specified width
Adjustment
..... Decrease the setting.
Instructions
• If the width of D in the test pattern is shorter than the specified width
..... Increase the setting.
ADF
X
X
X
X
X
D
Width of D in the copy)
/
key, change the setting value and then press the Select key.
ADJUSTMENT/SETTING
4139F3C548DA