Oki MC160MFP Maintenance Manual page 155

Diode color all in one printer
Hide thumbs Also See for MC160MFP:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
15.3.11
SOFT SWITCH: #11
14.3.11
SOFT SWITCH: #11
Bit No.
Designation
8
Reserved
Reserved
0: No
Detect dial tone after
7
pre-fix number
1: Yes
0: Yes
Pulse dial allowed to
6
select
1: Not allowed
0: Not to display
Protocol signal display
5
mode
1: Display V8 or T30 command within communication.
4
Reserved
Reserved
3
0: OFF
USB port number
2
fixed
1: ON
0: Base on SW23 (1 to 4)
DTMF low frequency
1
compensation
1: High 0.5 dB
• Bit 6: If this bit set to 1, not allowed user to select pulse dial, and this function open ser-
viceman to change.
• Bit 5: Bit set to 1, LCD will show the command between each party, the detail specifica-
tion see service mode specification.
44292401TH Rev.1
Initial
Function
Setting
Bit
HEX
0
0
2
1
0
0
0
0
0
0
15.3.12
SOFT SWITCH: #12
14.3.12
SOFT SWITCH: #12
Bit No.
Designation
1: Yes
8
ECM mode capability
0: No - also disable V.34 modem capability
7
Counter
V.34 fall back counter
Bit No. 7
for V.34 TX
Bit No. 6
6
0: Send CTC (Continue To Correct)
Send CTC after 4th
5
PPR
1: Send EOR (End Of Transmission)
4
Reserved
Reserved
0: Send DCN (Re-dial)
Send EOR after low-
3
est speed
1: Send EOR_xxx [Germany PTT]
2
Description (ms)
TCF transmission tim-
Bit No. 2
ing after DCS signal
Bit No. 1
1
• Bit 1-2: Delay time from FSK mode to PSK mode, this use for G3 mode only, V.34 do not
need this setting.
• Bit 6-7: If counter equal "1", machine will down to next lower speed for next data phase.
ADJUSTMENT/SETTING
Initial
Function
Setting
Bit
HEX
1
1
2
3
4
0
0
0
1
1
8
0
1
0
1
0
0
0
0
0
70
80
90
100
0
0
0
1
1
0
1
0
1
0
154 /