Oki Data CONFIDENTIAL
(2) V.34 Communication (example)
PROTOCOL MONITOR REPORT
NAME:TMFP
TEL :886 3 4733507
DATE:APR.10.2008 12:20
SESSION FUNCTION NO.
DESTINATION STATION
010
0001
TX
27187480
TX
RX
ANS
CM
V.8 PROTOCOL DUMP
JM
CJ
NSF
FF 03 20 00 00 25 00 00 00 12 10 6D 02 00 58 00 28 B8 A4 A0 80 91 60
NSF
FF 03 20 00 00 25 01 45 43 4E 45 59 45 4B
CSI
FF 03 40 30 38 34 37 38 31 37 32 20 20 20 20 20 20 20 20 20
DIS
FF 13 80 20 EE A8 C4 80 98 81 80 80 60
DCS
FF 13 83 00 02 F0 84 80 80 80 80 80 20
CFR
FF 13 84
►PIX
PPS-EOP
FF 13 BF 2F 00 00 7F
MCF
FF 13 8C
DCN
FF 13 FB
44292401TH Rev.1
DATE
TIME
PAGE
DURATION
MODE RESULT
OCT.27 17:19
008
OK
00h00min03s ECM
-33.6
DATA
A0FDF3C508DA
14.10 ADMIN. REGISTRATION
13.10 ADMIN. REGISTRATION
Function
• Use to display or change the current Administrator number.
Use
• Administrator number: 000000 to 999999
1. Enter the [SERVICE MODE].
Setting/
2. Select [ADMIN. REGISTRA TION] and press the Select key.
procedure
3. Check that the current ADMIN. No. is displayed and then press the [Back] key.
4. Enter the new ADMIN. No. from the 10-key pad and press the Select key.
14.11 FIXED ZOOM CHANGE
13.11 FIXED ZOOM CHANGE
Function
• The fixed zoom ratios can be changed.
Use
1. Enter the [SERVICE MODE].
Setting/
2. Select [FIXED ZOOM CHANGE] and press the Select key.
procedure
3. Select the fixed zoom ratio that you wish to change and press the Select key.
4. Use the 10-Key Pad to type in the desired fixed zoom ratio.
• Default fixed zoom ratios and setting ranges according to marketing area
<Metric>
Setting name
Initial fixed zoom ratio
REDUCTION2
REDUCTION1
EXPANSION1
115%
EXPANSION2
141%
<Inch>
Setting name
Initial fixed zoom ratio
REDUCTION2
REDUCTION1
EXPANSION1
129%
EXPANSION2
154%
14.12 FACTORY TEST
13.12 FACTORY TEST
• This test is for factory adjustment only and should NOT be used.
SIGNAL TEST
• This test is for factory adjustment only and should NOT be used.
RELA Y TEST
• This test is for factory adjustment only and should NOT be used.
SENSOR TEST
• This test is for factory adjustment only and should NOT be used.
DIAL TEST
• This test is for factory adjustment only and should NOT be used.
VOLUME TEST
• To check the volume of the speaker.
• To check the operation of the display and all indicators and buttons.
PANEL BUZZER TEST
• When the panel buzzer test are finish, press the panel reset key twice.
RAM TEST
• To test reading and writing of the memory.
ADJUSTMENT/SETTING
Setting range
70%
51% to 70%
81%
71% to 99%
101% to 140%
141% to 199%
Setting range
64%
51% to 64%
78%
65% to 99%
101% to 153%
154% to 199%
Functions/Use