Extended Administration
Additional feature: continuous connection verification
This mechanism is used to check whether there is still a TLS connection,
also then when the phone is not in use. If it determines that the original
server is not reachable, the phone can switch to a redundant server (if e.g.
DNS-SRV is used). This reduces longer waiting times for the user if the
phone would have to first register with the redundant server for the next
call and the call is then set up.

Implementation

optiPoint 410/420 SIP telephone settings
The following settings must be performed on the telephones for which
voice encryption is to be enabled:
The same settings can also be performed using the telephone menu. In
the case of web settings, references to the corresponding locations are
provided.
104
TLS verified
Set payload security to allowed (
Set connectivity check interval as required (
– (0, when deactivated; 10-3600 = duration of verification in seconds;
1-9 = 10; >3600 = 3600)
Set SIP server validation as required (
Set SIP transport to TLS (
Set SIP port to 5061 (
TLS verified
page 144)
page 144)
page 115)
page 115)
page 144)