Section 5: Wiring

The Fireplace A/C power and Power Vent harness's must be installed
before completing the installation of the H36PVN Fireplace. These
connections are made from the RH-Side of the fireplace, Figure 12
through Figure 12f.
Figure 12. Incoming A/C Power , (connect per. Local Codes).
Install the Power Vent connections as described
below:
Remove the exterior Access cover, shown Figure 12a.
Step 1.
Power Vent,
& A/C Access
Cover
Figure 12a. Remove Exterior Access Cover.
XG0649 - 180130
Installation
Incoming A/C
Power Connection
H36PVN Power Vent Indoor Gas Fireplace
Step 2. Locate all the Power vent connections & ports, Figure 12b.
Power Vent,
Communica-
tion port.
Power vent communi-
cation conduit, A/C
connection port
Figure 12b. Locate Power vent connections.
Note: To access the fireplace electrical connections from the
firebox follow the procedures described in figure 22 through 26.
Step 3.
Remove the Power Vent communication port cover from
cabinet, (as supplied) Figure 12c. (Philips head screwdriver
required).
Step 4.
Place the cover plate on the Conduit, then tighten the strain
relief nut onto the threads protruding through backside of cover plate,
Figure 12e.