Divine see-through indoor gas fireplace (44 pages)
Summary of Contents for Montigo H38DF ST
Page 1
Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 XG0146 150204.1...
SIT Proflame 2 Electronic Ignition Safety Alerts Honeywell Electronic Ignition Introduction Maintenance Congratulations on your purchase of a Montigo Fireplace. Lighting Instructions See pages 28 to 30. Section A: Before You Start Cleaning Installation Checklist Hi-Lo Burner Adjustment: (SIT Nova 820).
Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
Should it be impossible to meet the venting requirements laid ensure this fireplace is installed in compliance with the manufacturers out in Section 3: Venting, please contact a local Montigo dealer instructions and all applicable codes. regarding the use of a Montigo Power Vent.
H*38DF ST Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace. selecting the fireplace location.
H*38DF ST Indoor Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The Combustible material Backframe, framed opening for the assembled fireplace is 40¾" wide, x 42½" 2-pieces. Both Sides Typical. high x 23¾" deep, see Figure 2 Combustible Header Combustible Shelf NOTE: When constructing the framed opening, please ensure there is...
H*38DF ST Indoor Gas Fireplace Installation Installing The Standoffs Clearances To avoid elevated mantel temperatures, all H*38DF*-ST gas When installing a shelf over the top of the fireplaces, the following fireplaces are required to have the supplied standoffs installed. guidelines must be adhered to: The fireplace is supplied with four standoffs.
H*38DF ST Indoor Gas Fireplace Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be 8”...
H*38DF ST Indoor Gas Fireplace Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination PVTK1 Termination (PVTK-1) This section applies to installations where the direct vent termination will be roof mounted. Section 3-2-1: Venting Layout Selection of components and details of venting lay out should adhere to the following guidelines: The maximum termination point is 32’...
Page 12
H*38DF ST Indoor Gas Fireplace Installation PVTK1 Termination PEXT Solid Sectio 12” Max. Figure 10c. Side vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
H*38DF ST Indoor Gas Fireplace Installation Section 3-3: Installing a Wall Mounted Direct Vent 4). Installation of termination from inside structure Termination A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
If your installation does not fall within 42 ” the venting graph parameters, from center of the vent pipe. please contact a local Montigo dealer Venting runs must fall within the limits set by the venting graph, for Power Venting Options. ...
Page 15
Wall 42” If your installation does not fall within the venting graph parameters, 33 1/2” please contact a local Montigo dealer 12” for Power Venting Options. Hearth Figure 13c. Top Vented, wall mounted Retracted Multi-elbow installation. See Figure 14. Side Vent Venting Graph for wall mounted terminations.
Page 16
H*38DF ST Indoor Gas Fireplace Installation 192” Max Heat Sheild Termination Rigid Section Flex Exterior Section Hearth Figure 14c. Side Vented, wall mounted Multi-elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 14. Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
PEXT - 2 (24" f/m Section) possible hot spots. PEXT - 3 (36" f/m Section) Montigo recommends the use of a flex section for the final pipe PEXT - 4 (48" f/m Section) connected directly to the fireplace offering greater flexibility of PEXT - 6 (72"...
H*38DF ST Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination The RHS8 Heat shield CANNOT be used WITHIN 36" horizontal or (Figure 15 and 15a) CANNOT be used.
H*38DF ST Indoor Gas Fireplace Installation Section 4: Wiring Models Included H38FSDN-F OPTIONAL BATTERY PACK H38FSDL-F 1.5V AA type HL38FSDN-F 1.5V AA type SPARK GREEN 1.5V AA type HL38FSDL-F WHITE 1.5V AA type BLACK BLACK SENSOR To PPO TO ON/OFF BLUE WALL SWITCH BLUE...
Page 20
H*38DF ST Indoor Gas Fireplace Installation Installing the remote On/Off Wall Switch The H*38DF*ST gas valve may be connected to a wall switch. Do NOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace, depending on the model of the unit.
To check pressures, control valves have a provision to remove T.V. radio, and other electronic components. a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply. WARNING Only install gas shut-off valves approved for use by the state, ...
H*38DF ST Indoor Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing Around the Fireplace NOTE: National Canadian Gas Association mantel test requirements Combustible mantels and mouldings may be safely installed over the are for fire hazard prevention to combustible materials. top and on the front of the fireplace provided that they do not project New technology, to meet consumer and government demands for the beyond shaded area shown in Figure 22.
H*38DF ST Indoor Gas Fireplace Installation Section 7: Screen Installation and Removal Left Side Detail Upper Screen Removing / Attaching Screens: Removing Studs Upper Screen The Safet Stud Catch To Remove t To Remove Screens: Simply gra outer corne with your t finger and Grasp each top outer corner of the screen with your you.
H*38DF ST Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: The H*38DF*-ST doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch the Step 4: door buckles and, remove the door.
H*38DF ST Indoor Gas Fireplace Installation Removing the Door: Step 8: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 24g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
H*38DF ST Indoor Gas Fireplace Installation Section 8: Installing the Accessories Installing the Logs and Embers Bottom Logs The H38DF*-ST is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally Log C onto the supplied Log stands.
Page 27
The HL38DF*-ST has the option of installing the cultured rocks which mimic real stone. These may be spaced at random or in a visual pattern of your preference in the burner tray. See the Montigo web site for www.montigo.com photographs and ideas.
H*38DF ST Indoor Gas Fireplace Operation Section 9: Start-up Sequence For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation.
H*38DF ST Indoor Gas Fireplace Operation SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7.
H*38DF ST Indoor Gas Fireplace Operation Honeywell Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 8. If the fireplace does not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician 2.
H*38DF ST Indoor Gas Fireplace Maintenance Maintenance Lighting Instructions See pages 28 to 30. Hi-Lo Burner Adjustment: (SIT Nova 820). The H*38DF*ST is equipped with an adjustable burner, allowing you to General raise or lower the flames. To adjust the flames, locate the black knob Have the fireplace and installation inspected yearly.
If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 32 XG0207 - 150204.1...
Control Module RGC3063 Proflame Transmitter RSCH38 Replacement Screen All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 33 XG0207 - 150204.1...
H*38DF ST Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 12 inches 9 inches clearance to sides or bottom of door or operable windows...
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
H*38DF ST Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
Page 37
H*38DF ST Indoor Gas Fireplace Notes Notes Page 37 XG0207 - 150204.1...
Page 38
H38DF ST Residential Gas Fireplace XG0207 - 150204.1...