Montigo H38DF-ST Indoor Installation, Operation & Maintenance Manual

Hide thumbs Also See for H38DF-ST Indoor:

Advertisement

H38DF-ST Gas Fireplace
HL38DF-ST Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Canadian Heating Products Inc. Langley, BC V4W 4A
XG0207
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
www.montigo.com
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Montigo Del Ray Corp. Ferndale, WA 98248
H38DF-ST
Indoor
HL38DF-ST
Indoor
Warning:
Installer: Leave this manual
with the appliance.
Consumer: Leave this
manual for future reference.
092109

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF-ST Indoor

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. ® • Consumer: Leave this manual for future reference. Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 XG0207 092109...
  • Page 2: Table Of Contents

    Installation, Your new Montigo gas fireplace will give you years of durable, Operations and Maintenance manual. Pay special attention to all reliable use. Welcome to the Montigo family of gas fireplace cautions, warnings, and Important warnings.
  • Page 3: Introduction

    Liquid Propane. Warranty and Installation Information: ► H38DF-ST; Top or Rear Vent convertible, Millivolt Pilot The Montigo warranty will be voided by, and Montigo disclaims any ► H38DF-ST-I; Top or Rear Vent convertible, Intermittent Pilot (HSI) responsibility for, the following actions: ►...
  • Page 4: Installation

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Installing The Fireplace Shell (Minimum 1" clearance must still be maintained around the vent pipes, except on horizontal venting sections where the top of the pipe The fireplace may be installed in any location that maintains proper clear- must have a clearance of 2") ances to air conditioning ducts, electrical wiring and plumbing. Safety, For protection against freezing temperatures, it is recommended that as well as efficiency of operation, must be considered when selecting outer walls of the chase be insulated with a vapour barrier.
  • Page 5: Installing The Gasline

    10" W.C. Provision must also be made for a 1/8" N.P.T. plugged tapping Installation Requirements and be accessible for test gauge connection immediately upstream of H(L)38DF-ST Series fireplaces are certified for use with Montigo Standard  the gas supply controls to the appliance. The fireplace gas connection Series (5" / 8") venting components. and the main operating gas valve is located behind the removable trim Minimum clearance to combustible construction around the vent pipe is 1"...
  • Page 6: Vent Terminations

    Vent terminations can be very hot. If the termination is less than 7 feet  above a public walkway, it should be fitted with a certified Montigo Heat Guard. (Part no. PTKOG). Do not obstruct, or attempt to conceal the vent termination.
  • Page 7: Installing The Standoffs

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Ensure that the two long mounting brackets are facing the bottom Converting the H(L)38DF-ST from of the termination. (See inset). This will provide more heat protection Top Vent / Side Vent at the top of the termination, where temperatures are highest. Top Vent Attach to the faceplate of the termination using four sheet metal H(L38DF-ST Top / Side Vent...
  • Page 8: Top Vent Installation

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Top Vent Venting Requirements Installation Of Top Vent DV Before you install any venting, you must determine whether the A complete H(L)38DF-ST vent system may comprise up to five differ- venting run will be acceptable. Unacceptable venting can affect the ent types of components: fireplace's combustion.
  • Page 9 H(L)38DF-ST See-thru indoor Gas Fireplace Installation 1 MIN RHS 8 1 MIN. Both sides Typical RHS8 Heat Shield 1 MIN Figure 14. Heat Shield. Install by sliding over the vent pipe where it passes through combustible construction. Drywall RHS101 Heat Shield, RHS101 Heat Shield, Figure 11.
  • Page 10 H(L)38DF-ST See-thru indoor Gas Fireplace Installation 32’ max 32’ max Figure 16. Straight, vertical venting. * If reducing to 4"/7" venting see Figure 19. A maximum of two offsets (each offset has two 90° bends) may  be made if the length of the offsets does not exceed 25% of the vertical vent height, when measured center to center of piping.
  • Page 11: Rear / Side Vent Installation

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Side Vent Venting Requirements Horizontal Vent Installation If your installation requires more than 12" of horizontal venting, some Vent systems that terminate through a wall may comprise up to seven vertical lift is required. Use the vent graph below to determine an different components: acceptable vent run. Unacceptable venting can affect the fireplace's A - Termination...
  • Page 12 H(L)38DF-ST See-thru indoor Gas Fireplace Installation Heat Shields RHS8 Due to high flue temperatures, the heat shield (RHS101) must be used on all installations straight through the wall, at the point where the vent pipe connects to the termination. With the heat shield, vent clearances can be maintained at 1". The heat shield is not included with the fireplace.
  • Page 13: Power Vent Terminations

    There are four 5/7 Power Vent models available. These Power Vents are required for Superior venting, safe operation & years of trouble free operation. The available Montigo Power Vent models are: LDVPV47/58 (Linear, Interior In-line Power Vent, document, XG0700). EDVPV47/58 (External Power Vent Module, document, XG0750).
  • Page 14: Finishing Around The Fireplace

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Finishing Around the Fireplace Mantels & Surrounds NOTE: Mantel clearances are for fire hazard prevention to combus- Combustible mantels and mouldings may be safely installed over the tible materials. top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 27. Side wall clearances are 0". New technology, to meet consumer and government demands for the Combustible surrounds may be installed with 0"...
  • Page 15: Wiring

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Wiring Wiring for the optional Fan Kit H(L)38DF- ST The H(L)38DF-ST fireplace may be equipped with optional fan kits for Gas Control and Pilot Wiring H(L)38DF-ST-I circulating heat into the living space. Installations in Canada which employ the fans must be electrically Honeywell (Q3450) grounded in accordance with CSA C22.1 Canadian Electrical Code Pilot Assembly Part 1 and/or Local Codes.
  • Page 16: Removing And Installing The Door

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation Removing and Installing the Door Step 5: Ensure the tool is firmly Removing the door: in the lower end of the The H(L)38DF-ST Series doors are removed in a few simple steps. Follow slot, (as shown), Then pull these Steps below to remove the Horizontal access panel, unlatch the toward you (Caution: hold door buckles and, remove the door.
  • Page 17: Installing Logset

    H(L)38DF-ST See-thru indoor Gas Fireplace Installation H38DF-ST Installing the Logs and Embers Bottom Logs The H38DF-ST is supplied with eight (8) fibre logs. The two small Log C bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands. The long Front / Back logs ("B") are placed against the grate as shown in Figure 36b.
  • Page 18: Installing Designer Glass Beads

    Figure 38b. Spreading designer beads evenly . The HL38DF-ST fireplace has the option of installing the cultured rocks which mimic real stone. These may be spaced at random, or in a visual pattern of your preference. See the Montigo web site for photographs and ideas. www.montigo.com Figure 39c. Completed glass bead installation.
  • Page 19: Lighting Instructions

    H(L)38DF-ST See-thru indoor Gas Fireplace Operation - Model H38DF-ST H38DF-ST with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 20 H(L)38DF-ST See-thru indoor Gas Fireplace Operation - Model H38DF-ST-I H38DF-ST-I HL38DF-ST-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 21 H(L)38DF-ST See-thru indoor Gas Fireplace Operation - Model H38DF-ST-F HL38DF-ST-F H38DF-ST-F with Proflame SIT Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 22: Operation

    H(L)38DF-ST See-thru indoor Gas Fireplace Operation Maintenance Lighting Instructions General See pages 19 to 22. Have the fireplace and installation inspected yearly. The inspection  must include, but is not limited to, the following: Burner Adjustment • A visual check of the entire vent system and termination. The H38DF-ST is equipped with an adjustable burner, allowing you to • An inspection of the explosion relief flappers and the door raise or lower the flames. To adjust the flames, locate the black knob...
  • Page 23: Spare Parts

    H(L)38DF-ST See-thru indoor Gas Fireplace Maintenance Gas Control Valve WARNING! Power Do not attempt to clean glass when hot. Generator Do not clean glass with abrasive materials as any glass etching Pilot Adjustment Screw may cause premature glass failure. Wall Switch Do not operate this fireplace without the glass door, or with a broken glass door.
  • Page 24: Troubleshooting

    H(L)38DF-ST See-thru indoor Gas Fireplace Maintenance Troubleshooting Troubleshooting H38DF-ST-I The following is a troubleshooting chart of possible problems: HONEYWELL SV9500 /9600 PRoBLEM CoRRECtIVE ACtIon Troublshooting Sequence Noisy Pilot Flame Locate pilot adjustment screw on the NOTE: Before Troubleshooting, Familiarize Yourself With front of the gas control valve.
  • Page 25: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 26: Termination Locations

    H(L)38DF-ST See-thru indoor Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [16 inches (41 cm) minimum] property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [16 P = c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y...
  • Page 27: B State Of Massachusetts / Amendment

    H(L)38DF-ST See-thru indoor Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 28: Notes