H36PVN Power Vent Indoor Gas Fireplace
Installing the external roof mounted power vent module
Step 1.
Construct a Vertical Chase for the termination opening to meet
the following requirements:
Opening Size must be:
14½"
Figure 5. Construction, Rough-in framing.
Step 2.
Install the Vent pipe female end up, and 2" to 3" MAX. from the
top of the Constructed Chase. Also, at this point install the Electrical
harness, (EPVH-(10-100) that will communicate with the Power
Vent Module.
2" to 3" Max.
Vent Chase
Figure 5a. Installation, Vertical Vent pipe. (female end top end).
Page 12
Installation
14 1/2" x 14 1/2" x 18" Min. height.
14½"
18"
Electrical Harness
with connection
Vent Pipe
Step 3.
Install the Power Vent Rough-in Kit. Pull wire harness through
the supplied hole in the bottom corner of the rough-in box, and snap
into the slot provided, (See figure 5b inset).
Electrical Harness
Connerctor Location
Figure 5b. Installation of Rough-in Kit
Step 4.
Install fasteners around perimeter of Rough-in Kit. (Holes supplied
for ease of installation)
Figure 5c. (Fasten Rough-in Kit to framing)
Figure 5d. (Installed Stainless steel cover)
Power Vent
Rough-in Kit
Electrical
Harness
Install Fasteners around
perimeter of Rough-in Kit
XG0649 - 180130