Montigo H38DF PFC Installation & Maintenance Manual

Peninsula indoor residential gas fireplace

Advertisement

Installation & Maintenance Manual
DANGER
Lighting Instruction Updates
Lighting Instruction Updates
Lighting Instruction Updates
Lighting Instruction Updates
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
Replace the warning label with danger label in the
Replace the warning label with danger label in the
Replace the warning label with danger label in the
Replace the warning label with danger label in the
agency or the gas supplier.
Lighting instructions
Lighting instructions
Lighting instructions
Lighting instructions
XG0816
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H38DF PFC
HL38DF PFC
HP38DF PFC
Peninsula
Indoor
Residential Gas
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
150204.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF PFC

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects XG0816 150204.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H*38DF PFC Peninsula Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Operation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 28 INTRODUCTION �...
  • Page 3: Introduction

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Before You Start

    Should it be impossible to meet the venting requirements laid „ Before You Start: out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Rating Plate Sample

    H*38DF PFC Peninsula Gas Fireplace Installation Rating Plate Sample Figure A: Rating Plate for IPI eletronic ignition Figure B: Rating Plate for standing pilot (SIT) Page 5 XG0816 - 150204.1...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    H*38DF PFC Peninsula Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Safety, as well as efficiency of operation, should be considered when Please review the Installation Checklist on Page 4 for general information selecting the fireplace location. Select a location that does not interfere on preparing for a successful installation of your fireplace.
  • Page 7: Section 2: Framing

    H*38DF PFC Peninsula Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The Top Vent framed opening for the assembled fireplace is 23 3/4" wide, x 44" Ceiling level high x 41" deep, see Figure 2 Non-Combustible materials.
  • Page 8: Clearances

    H*38DF PFC Peninsula Gas Fireplace Installation Nailing Flange Extension Clearances The 4" nailing flange extension is shipped attached to the top edge of When installing a shelf over the top of the fireplaces, the following the fireplace, see Figure 1. guidelines must be adhered to: For Rear Vent applications, the minimum clearance is 2"...
  • Page 9: Section 3: Venting

    Section 3: Venting 3. Install the (removed) Rear flue cover and gasket material, to the Montigo supplies a variety of direct venting and termination options. Top vent outlet. Fasten the cover with included hardware, as The direct vent termination location MUST be selected such that illustrated Figure 8a.
  • Page 10: Installing A Roof Mounted Direct Vent

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted� Support ring Section 3-2-1: VENTING LAYOUT Selection of components and details of venting lay out should Support plate 32’...
  • Page 11 H*38DF PFC Peninsula Gas Fireplace Installation PVTK1 Termination Support plate 32’ Ma. x Support ring 12” Max. Figure 9c� Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 12: Installing A Wall Mounted Direct Vent

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT TERMINATION 4)� Installation of termination from inside structure This section applies to installations where the direct vent termi- A Termination with a MOSR Frame is installed from the inside of the nation will be wall mounted�...
  • Page 13: Section 3-3-1: Venting Layout: Wall Mounted Termination

    If your installation does not fall with- NOT be an acceptable installation� in the venting graph parameters, please contact a local Montigo Example C: (Unacceptable Installation) dealer for Power Venting options. If the vertical dimension from the floor of the fireplace is 60" and the horizontal run to the wall flange of the vent termination is 144",...
  • Page 14 H*38DF PFC Peninsula Gas Fireplace Installation Heat 150” Max. Shield Note: Images are shown without screens for clarity purposes. However, Termination your fireplace should not be operated without proper installation of Solid screens. Section Flex Section Exterior Wall Hearth Figure 13b. H38PF* , HL38PF* or HP38PF* Top Vented, wall mounted Multi- elbow installation.
  • Page 15 12 ” contact a local Montigo dealer for the wall flange of the termination. Plot on the Venting Graph Figure 14 Power Venting options.
  • Page 16 H*38DF PFC Peninsula Gas Fireplace Installation 42” Max. Flex or Rigid Section Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of 20”Min. screens. 53” Min. 12” Max. 33” Hearth Figure 15a�...
  • Page 17: Section 3-3-2: Venting Components

    FS-8 possible hot spots. H - Roof Flashing PRF-7 (1/12 - 7/12 pt�) Montigo recommends the use of a flex section for the final pipe „ PRF-12 (7/12 - 12/12 pt�) connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 18: Section 3-3-3: Heat Shields

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield� Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 16 and 16a) CANNOT be used. Use the RHS101 within 36" The RHS8 Heat shield CANNOT be used WITHIN 36"...
  • Page 19: Section 4: Wiring

    H*38DF PFC Peninsula Gas Fireplace Installation Section 4: Wiring Models Included H38DFPFCN-F HL38DFPFCN-F HP38DFPFCN-F BATTERY H38DFPFCL-F HL38DFPFCL-F HP38DFPFCL-F PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type WHITE BLACK 1.5V AA type BLACK SENSOR To PPO MAIN ON/OFF SWITCH BLUE 885 PROFLAME...
  • Page 20: Section 5-1: Fuel Conversion

    When pressure testing the fireplace, Gas line, and input system follow the appropriate local codes or your area. DO NOT connect the fireplace to pressures in excess of Montigo requires a service shut off valve be located in an „...
  • Page 21: Section 6: Finishing Around The Fireplace

    H*38DF PFC Peninsula Gas Fireplace Installation Section 6: Finishing Around the Fireplace Mantels & Surrounds Combustible mantels and mouldings may be safely installed over the NOTE: National Canadian Gas Association mantel test requirements top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 22: Section 7: Screen Installation And Removal

    H*38DF PFC Peninsula Gas Fireplace Installation Section 7: Screen Installation and Removal Left Side Detail Upper Screen Removing / Attaching Screens: Removing / A Studs Upper Screen The Safety Sc Stud Catch To Remove the scr Simply grasp ea To Remove Screens: outer corner of with your thum finger and pull...
  • Page 23: Section 8: Installing & Removing The Door

    H*38DF PFC Peninsula Gas Fireplace Installation Section 8: Installing & Removing the Door WARNING Step 4: When reinstalling door(s), always make sure all door Firmly grasp hand-hold buckles are properly hooked and fully engaged. end of Door buckle tool and place the machined end in the slot under door frame.
  • Page 24: Removing The Door

    H*38DF PFC Peninsula Gas Fireplace Installation Removing the Door: Step 8: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 24g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
  • Page 25: Section 9: Installing The Accessories

    H*38DF PFC Peninsula Gas Fireplace Installation Section 9: Installing the Accessories Installing the H38PF* Logset The H38PF* is supplied with eight (8) fibre logs. The two small bottom Log C logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands�...
  • Page 26: Installing The Hp38Pf* Logs And Embers

    H*38DF PFC Peninsula Gas Fireplace Installation Installing the HP38PF* Logs and Embers Bottom Logs The HP38PF* is supplied with seven (7) fibre logs. The two bottom logs Log F ("A" & "B") are mounted on the burner grate as shown in Figure 26a� Top Logs Place logs "C"...
  • Page 27 The HL38PF* has the option of installing the cultured rocks which mimic real stone. These may be spaced at random or in a visual pattern of your preference in the burner pan. See the Montigo web site for photographs www.montigo.com and ideas.
  • Page 28: Operation

    H*38DF PFC Peninsula Gas Fireplace Operation Lighting Instruction Updates Lighting Instruction Updates Lighting Instruction Updates Lighting Instruction Updates Operation Replace the warning label with danger label in the Replace the warning label with danger label in the Replace the warning label with danger label in the Replace the warning label with danger label in the For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition...
  • Page 29 H*38DF PFC Peninsula Gas Fireplace Operation SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7.
  • Page 30: Honeywell Electronic Ignition

    H*38DF PFC Peninsula Gas Fireplace Operation Honeywell Electronic Ignition Lighting Instructions: 1� STOP! Read the safety information above on this label. 8� If the fireplace does not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician 2�...
  • Page 31: Maintenance

    H*38DF PFC Peninsula Gas Fireplace Maintenance Maintenance Lighting Instructions See pages 25 to 27. CAUTION General Have the fireplace and installation inspected yearly. The „ Due to high operating temperatures, this appliance should be located out of traffic & inspection must include, but is not limited to, the following: away from furniture and draperies.
  • Page 32: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician� All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 32 XG0816 - 150204.1...
  • Page 33: Replacement Parts

    NG Gas Valve RDTH38PF01 RDTH38PF01 RGC1005 LP Gas Valve RDTH38PF02 RPA020 NG Pilot RDTH38PF02 RPA021 LP Pilot NG Burner Contact Local Montigo Dealer RSCH38PFC3 NAME DATE Description DIMENSIONS ARE IN INCHES LP Burner TOLERANCES: 11/27/2014 Drawn by FRACTIONAL 1/32" TWO PLACE DECIMAL .015"...
  • Page 34: Appendix A: Venting Terminations

    H*38DF PFC Peninsula Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 12 inches 9 inches clearance to sides or bottom of door or operable windows...
  • Page 35: Appendix B: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 36: Appendix C: State Of Massachusetts

    H*38DF PFC Peninsula Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10�5�4�2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10�8�3 by...
  • Page 37 H*38DF PFC Peninsula Gas Fireplace Notes Notes Page 37 XG0816 - 150204.1...
  • Page 38 H38DF PFC Peninsula Gas Fireplace 150204.1 XG0816 -...

This manual is also suitable for:

Hl38df pfcHp38df pfc

Table of Contents