Montigo H38SVO-ST Installation And Maintenance Manual

Outdoor ventless see through residential gas fireplace

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
WARNING
FOR OUTDOOR USE ONLY.
XG0817
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H38SVO-ST
HL38SVO-ST
Outdoor Ventless
See Through
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
WARNING
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has
no odor. Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a
camper, tent, car or home.
140707.2

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38SVO-ST

  • Page 1 Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home. XG0817 140707.2 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H*38VO-ST Outdoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents .................3 Introduction Models .................3 Installation Before you Start .................4 Installation Checklist ................4 Section 1: Installation Overview and Product Dimensions .....5...
  • Page 3: Introduction

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards. We strongly encourage you to read and carefully follow the instructions...
  • Page 4: Installation

    H*38VO-ST Outdoor Gas Fireplace Installation Installation Checklist IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS Determine the desired install location of your fireplace. The H*38VO-ST Ventless fireplace must be installed in accordance „ with these Instructions. Carefully read all the Instructions in this manual See Section 1, Dimensions on Page 5, and refer to the Framing „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*38VO-ST Outdoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace. selecting the fireplace location. Try to select a location that does not interfere with room traffic and has adequate ventilation. The H*38VO-ST* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. The fireplace dimensions are shown below: 24" 36½" 24” Height Top View Side View...
  • Page 6: Section 2: Framing The Fireplace

    be non-combustible materials, metal studs, concrete board and concrete, brick, or stone. H*38VO-ST Outdoor Gas Fireplace Installation Backframe Min. 38" both sides Typical Section 2: Framing Clearances Installing The Fireplace The fireplace must be installed in a location that maintains clearances to When installing a shelf over the top of the fireplaces, the following 41" ALL exterior furniture, appliances and other exterior equipment. Safety, guidelines must be adhered to: as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with Surrounding construction bottom, sides and top) must foot traffic, has adequate ventilation, and offers an accessible pathway be non-combustible materials, for ventilated gasses.
  • Page 7: Finishing Around The Fireplace

    H*38VO-ST Outdoor Gas Fireplace Installation Follow Figures 4,5 (wall installation) and Figure 3 (MIN size enclosure Fireplace Facing for patio or other contemporary installation) to frame around the fireplace When selecting the finish material for your fireplace, it is important to chassis. remember the following: THE LOWER GAS CONTROL PANEL MUST NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply Note: ONLY Non-combustible materials must be used in construction of the enclosure. (top, bottom and sides). Steel studs in combination for the control compartments and heat exchanger it also prevents with concrete, rock, or stone finishing materials, are acceptable. See access for servicing controls.
  • Page 8: Section 3: Wiring

    The H*38VO-ST* gas valve, located behind the lower trim, may be connected to a wall switch. The valve generates its own power on a Use Montigo Part No. #RPOVO Water-tight electrical box, or millivolt circuit. Use only low voltage wire, and DO NOT connect equivalent equipment. Ensure the box is installed in a dry location...
  • Page 9: Section 4: Installing The Gas Line

    The manifold outlet pressure is set from the factory to the „ appropriate pressure but should be verified. To check pressures, control valves have a provision to remove „ a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply. Only install gas shut-off valves approved for use by the state, „ province, or other governing body in which the fireplace is being installed.
  • Page 10: Section 5: Installing And Removing The Door

    H*38VO-ST Outdoor Gas Fireplace Installation Section 5: Installing & Removing the Door Removing the door: The H*38VO-ST* doors can be removed in a few steps. Follow below Step 5: to remove the Horizontal access panel, unlatch the door buckles and, Ensure the tool is firmly remove the door. Replace the door in reverse order. in the lower end of the slot, (as shown), Then pull toward you (Caution: hold Step 1: Remove the Horizontal Access Panel:...
  • Page 11: Section 6: Installing The Accessories

    H*38VO-ST Outdoor Gas Fireplace Installation Section 6: Installing the Accessories Installing the Logs and Embers Bottom Logs Log C The H38VO-ST* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands. The long Front / Back logs ("B") are placed against the grate as shown in Figure 11c. Note: When Log C placing logs, arrange Logs "B" as not to cover Burner holes.
  • Page 12: Installing The H38Vo Log Set - Glass Beads

    H*38VO-ST Outdoor Gas Fireplace Installation Installing the Glass Beads The HL38VO-ST* is supplied with Designer Glass beads. Remove the Door as shown on page 11. Once the glass door(s) are removed place the glass beads across the pan surrounding the burners as shown in Figure 12. L42DF-ST NOTE: DO NOT Cover burners with beads or the optional rocks. Figure 12. Installation of glass beads . Note: Ensure the beads do not cover the burners or pilot. Page 12 XG0817 - 140707.2...
  • Page 13: Section 7: Operation

    H*38VO-ST Outdoor Gas Fireplace Operation Section 7: Start-up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 14: Start-Up Sequence With Honeywell Electronic Ignition

    H*38VO-ST Outdoor Gas Fireplace Operation Section 7: Start-up Sequence Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 15: Maintenance

    H*38VO-ST Outdoor Gas Fireplace Maintenance Burner Adjustment Lighting Instructions The H*38VO-ST* is equipped with an adjustable burner, allowing you See pages 14 to 15. to raise or lower the flames. To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure 13). General The front burners are not adjustable. Have the fireplace and installation inspected yearly. The „ „ To raise the flame height, turn the black knob (located behind the inspection must include, but is not limited to, the following: lower trim) counterclockwise. • A visual check of the entire vent system and termination. „...
  • Page 16: Pilot Burner Adjustment

    H*38VO-ST Outdoor Gas Fireplace Maintenance Gas Control Valve Troubleshooting Power Generator Pilot Adjsutment Screw Wall Switch Inlet Pressure Manifold Pressure Test Connection Figure 14. Sit Nova 820 gas valve. Pilot Burner Adjustment 1. Locate Pilot Adjustment Screw. (See figure 14.) 2. Adjust pilot screw to provide properly sized flame as shown in figure 15).
  • Page 17: Appendix

    In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you. Investigation Of Claims Against Warranty The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
  • Page 18: State Of Massachusetts

    H*38VO-ST Outdoor Gas Fireplace Appendix Appendix B: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1.
  • Page 19 H*38VO-ST Outdoor Gas Fireplace Notes Page 19 XG0817 - 140707.2...
  • Page 20 H38VO ST Ventless Outdoor See Through Residential Gas Fireplace XG0817 - 140707.2...

This manual is also suitable for:

Hl38svo-st

Table of Contents