Montigo H38VO-ST Installation & Maintenance Manual

Outdoor ventless see through residential gas fireplace

Advertisement

Quick Links

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
WARNING
FOR OUTDOOR USE ONLY.
XG0817
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H38VO-ST
HL38VO-ST
Outdoor Ventless
See Through
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
WARNING
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has
no odor. Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a
camper, tent, car or home.
080311

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38VO-ST

  • Page 1 Using it in an enclosed space can kill you. ® Never use this appliance in an enclosed space such as a camper, tent, car or home. XG0817 080311 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H*38SVO-ST Outdoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. XW2010 Table of Contents .................3 Introduction Models .................3 Installation Before you Start .................4 Installation Checklist ................4 Section 1: Installation Overview and Product Dimensions .....5...
  • Page 3: Introduction

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    H*38SVO-ST Outdoor Gas Fireplace Installation Installation Checklist IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS Determine the desired install location of your fireplace. The H38SVO Ventless fireplace must be installed in accordance with „ these Instructions. Carefully read all the Instructions in this manual See Section 1, Dimensions on Page 5, and refer to the Framing „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*38SVO-ST Outdoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace. selecting the fireplace location.
  • Page 6 Surrounding construction (bottom, sides and top) must be non-combustible materials, H*38SVO-ST Outdoor Gas Fireplace metal studs, concrete board and concrete, brick, or stone. Installation Section 2: Framing Backframe Min. 38" both sides Typical Installing The Fireplace Shell Framing (stand-alone): The fireplace may be installed in a location that maintains clearances to For Fireplace without the Optional Stainless steel surround.
  • Page 7 H*38SVO-ST Outdoor Gas Fireplace 41" Installation Surrounding construction (bottom, sides and top) must When installing this fireplace as shown in Figure 5, the outer shell is not be non-combustible materials, Fireplace Facing to be installed. Follow Figures 4,5 (wall installation) and Figure 3 (MIN metal studs, concrete board When selecting the finish material for your fireplace, it is important to and concrete, brick, or stone.
  • Page 8: Section 4: Wiring

    The valve generates its own power on a millivolt circuit. Use only low voltage wire, and DO NOT connect Montigo Part No. #HSIT07 must be encased in a water-tight any external power to it. electrical box OR ensure the box is installed in a dry location and avoid any moisture.
  • Page 9: Section 5: Installing The Gas Line

    When pressure testing the fireplace, Gas line, and input system follow the appropriate local codes or your area. DO NOT connect Montigo requires a service shut off valve be located in an „ the fireplace to pressures in excess of 1/2lb. This will damage the accessible location to isolate the gas supply.
  • Page 10: Section 6

    H*38SVO-ST Outdoor Gas Fireplace Installation Section: Section 7: Installing & Removing the Door Removing the door: The H-Series VO doors are removed in a few simple steps. Follow these Step 5: below to remove the Horizontal access panel, unlatch the door buckles Ensure the tool is firmly and, remove the door.
  • Page 11: Section 8: Installing The Accessories

    Section 8: Installing the Accessories Installing the Logs and Embers Bottom Logs The H38VO-ST is supplied with eight (8) fibre logs. The two small bottom Log C logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands.
  • Page 12 H*38SVO-ST Outdoor Gas Fireplace Installation WARNING! Do not attempt to clean glass when hot. L42DF-ST Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. Do not operate this fireplace without the glass door, or with a broken glass door.
  • Page 13: Section 9: Operation

    H*38SVO-ST Outdoor Gas Fireplace Operation Section 9: Start-up Sequence with Continuous Pilot with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 14: Lighting Instructions

    H*38SVO-ST Outdoor Gas Fireplace Operation Section: with Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. If you cannot reach your gas supplier, call the Fire Department.
  • Page 15: Maintenance

    H*38SVO-ST Outdoor Gas Fireplace Maintenance Section: Burner Adjustment Lighting Instructions The H-Series VOST is equipped with an adjustable burner, allowing See pages 13 to 14. you to raise or lower the flames. To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure General 11).
  • Page 16: Pilot Burner Adjustment

    H*38SVO-ST Outdoor Gas Fireplace Maintenance Gas Control Valve Troubleshooting Power Generator Pilot Adjsutment Screw Wall Switch Inlet Pressure Manifold Pressure Test Connection Figure 33. Sit Nova 820 gas valve. Pilot Burner Adjustment 1. Locate Pilot Adjustment Screw. (See figure 33.) 2.
  • Page 17: Appendix

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 18: State Of Massachusetts

    H*38SVO-ST Outdoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 19 H*38SVO-ST Outdoor Gas Fireplace Notes Page 19 XG0817 - 080311...
  • Page 20 H38VO ST Outdoor Residential Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0817 - 080311...

This manual is also suitable for:

Hl38vo-st

Table of Contents