Montigo H36PVN Installation & Maintenance Manual page 17

Power vent indoor gas fireplace
Table of Contents

Advertisement

Figure 7e. (Assembled Rough-in Kit)
Step 8.
Install the Power Vent Power / communication harness. Hold
the Power Vent in close proximity of the assembled Rough-in Kit,
and plug in the Power Vent communication / Power Cord. (Note the
direction and orientation of the pins inside the Power Vent connector,
snap together). (Figure 7f).
Figure 7f. (Installation of Power Vent communication harness)
Step 9.
Install the Power Vent. Place the Power Vent into the Rough-in
frame, aligning the Power Vent into final position. Ensure the Harness
is placed down in the Rough-in box when placing the Power Vent.
(Secure the Power Vent in Place with the supplied hardware).
Tightened hardware,
4-pcs.
Figure 7g. (Completed Installation of Power Vent)
XG0649 - 180130
Installation
Installed Power Vent
Connector
Tightened hardware, 6-pcs.
TOP of Power Vent,
Communication
(Note Quantity of
Harness.
louvers).
Note louver
direction
H36PVN Power Vent Indoor Gas Fireplace
CAUTION
■ Vent terminations can be very hot. The termination is to be installed higher than 7 feet
above a public walkway.
■ Do not obstruct, or attempt to conceal, the vent termination. These actions will affect the
operation of the fireplace, and may be hazardous.
■ In heavy snow areas, take extra care to prevent snow buildup from obstructing the vent
termination.
Page 17