Installing the remote On/Off Wall Switch
The L38DF-ST* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the fireplace, depending on the model of the
unit. Use only low voltage wire, and DO NOT connect any external
power to the remote switch.
Refer to Figure 16 or 17 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.
NOTE:
If any of the original wire supplied with the appliance is
replaced, it must be replaced with the same type, or its
equivalent.
Wiring for the optional Fan Kit
All L38DF-ST* fireplaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
5/1/60 Supply
G
L1 L2
Quick Connect
Figure 18. Wiring schematic for optional fans.
Page 18
Installation
L2-WH
G
L1-BLK
p g
lu to motor
XG0810 - 070714