Montigo H34DF Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
XW2002
XW2004
XG0146
DANGER
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage
or
even
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
death.
For
XW2006
XW2012
XW2014
H34DF HC34DF
HL34DF HR34DF
Indoor
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
NOTICE
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
supplier's instructions.
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
If you cannot reach your gas supplier,
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
call the fire department.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
042811

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H34DF

  • Page 1 Danger of harming radiation Environment your hands Irritant Slippery floor Watch your step Cutting High temperatures Glass hazard Danger of suffocation XW2014 XG0146 042811 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    ▪ Roof mounted Terminations Section 8: Installing the Accessories ..........22 - 26 Standard Top Vent (no elbows or offsets) ........9 ▪ Installing the H34DF* Log Set ...........22 Top Vent (two elbows one offset) ..........9 ▪ Installing the HC34DF* Log Set ..........23 Top Vent (multi-elbows and offsets) ...........9...
  • Page 3: Introduction

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ BEFORE YOU START: out in Section 3: Venting, please contact Montigo regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*34DF Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions 0" clearance 0" cl to corners onl y to co Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace.
  • Page 6: Section 2: Framing The Fireplace

    43” 0" clearance to corners only 2” min. to corners only 2” min. Exterior Exterior Wall Wall H34DF, HL34DF & HR34DF HC34DF ONLY, see figures 7 and 24a. Q” M” Q” N” N” P” P” Figure 4. Combustible Framing for shelves over the fireplace, Top vent.
  • Page 7: Clearances

    A clearance to maintains a 6" clearance. combustibles of 9" for H34DF, HC34DF , & HL34DF & 11" for HR34DF is required to the underside of any combustible shelf materials, Figure 3.
  • Page 8: Section 3: The Direct Vent System

    Figure 9a. be impossible to ensure that the termination is the highest point or to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options. nOTES FOR PLannInG VEnTInG:...
  • Page 9: Section 3-2: Installing A Roof Mounted Termination

    H*34DF Indoor Gas Fireplace Installation Section 3-2: InSTaLLInG a ROOF MOUnTED DIRECT VEnT TERMInaTIOn (MVTK-1) MVTK1 PVTK1 Termination This section applies to installations where the direct vent termination Termination 2’ min. will be roof mounted. Section 3-2-1: VEnTInG LaYOUT: Roof Mounted Termination Support ring Selection of components and details of venting lay out should Support plate...
  • Page 10: Standard Roof Vent (One Elbows No Offsets)

    18” possible hot spots. Max. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend).
  • Page 11: Section 3-3: Installing A Wall Mounted Termination

    H*34DF Indoor Gas Fireplace Installation Section 3-3: InSTaLLInG a waLL MOUnTED DIRECT VEnT 4). Installation of termination from inside structure TERMInaTIOn A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction. This section applies to installations where the direct vent termination will be wall mounted.
  • Page 12: Section 3-3-1: Venting Layout

    All through-the–wall terminations within 3’ of the fireplace must have a If your installation does not fall within the venting graph parameters, (non- Montigo Heat Shield (RHS100) installed. See Section 3-3-3. Shaded area) please contact Montigo for Power Venting options.
  • Page 13: Rear Vent, Wall Mounted Graph, H*34Df

    Figure 16. If your installation does not fall within the venting graph parameters, (non- Shaded area) please contact Montigo for Power Venting options. Horizontal Run (in.) Figure 16. H*34DF* Rear Vent Venting Graph for wall mounted terminations, See Figures 16a &...
  • Page 14: Rear Vent, Wall Mounted Termination (45° Corner)

    „ and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 15: Section 3-3-3: Heat Shields

    H*34DF Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a wall Mounted RHS100 Heat shield. Installing a wall Mounted RHS8 Heat shield The RHS8 Heat shield CannOT be used wITHIn 36" horizontal or The RHS100 Heat shield MUST be used where the RHS8 Termination 39"...
  • Page 16: Section 4: Wiring

    H*34DF Indoor Gas Fireplace Installation Section 4: wiring Models Honeywell (Q3450) H34DFnE Pilot Assembly H34DFLE HC34DFnE Pilot Electrical HC34DFLE Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Junction Box Fan Plug Receptacle Black 115VAC White 24VAC Green Gnd Screw 40 VA Transformer Wall Switch...
  • Page 17: Sit - Ipi Gas Control And Pilot

    H*34DF Indoor Gas Fireplace Installation Models H34DFnI HL34DFnI H34DFLI HL34DFLI HC34DFnI HR34DFnI HC34DFLI Figure 21. Wiring for the SIT IPI Wiring Schematic Wiring for the optional Fan Kit All H*34DF* fireplaces may be equipped with optional fan kits for nOTE: If any of the original wire supplied with the appliance is replaced, it must be replaced with the same type, or its equivalent.
  • Page 18: Section 5: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. follow the appropriate local codes or your area. DO NOT connect Montigo requires a service shut off valve be located in an „ the fireplace to pressures in excess of 1/2lb. This will damage the accessible location to isolate the gas supply.
  • Page 19: Section 6: Finishing

    WARNING! Combustible mantels and mouldings may be safely installed over the top and on the front of the H34DF, HL34DF & HR34DF fireplaces When covering the upper metal portion of the fireplace, (HC34DF provided that they do not project beyond shaded area shown in Figure OnLY) up to 3"...
  • Page 20 H*34DF Indoor Gas Fireplace Installation Mantels & Surrounds CAUTION nOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. New technology, to meet consumer and government demands for the Due to high operating temperatures, this appliance wise use of energy, has prompted us to manufacture many models of should be located out of traffic &...
  • Page 21: Section 7: Installing And Removing The Door

    H*34DF Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: The H*34DF* doors are removed in a few simple steps. Follow these Step 5: below to remove the Horizontal access panel, unlatch the door buckles Ensure the tool is firmly and, remove the door.
  • Page 22: Section 8: Installing The Accessories

    Installing the Logs: log, as shown in figure 27c. Install the glass door. If the flame The H34DF* fireplace is supplied with five ceramic fibre logs. Unpack does not appear satisfactory, double-check the air inlet and the logs and handle them very carefully.
  • Page 23: Installing The Hc34Df* Log Set

    H*34DF Indoor Gas Fireplace Installation Installing the HC34DF* Log Set Step 3. Place the left two logs, and the centre log shown below in (Previous model figure 28d. HD34DF) Installing the Logs: The HC34DF* is supplied with a seven piece ceramic fibre logset. Unpack Step 1.
  • Page 24: Installing The Hl34Df* Firestones

    The H*34DF* has the option of installing the cultured rocks which mimic real stone. These may be spaced at random, or in a visual pattern of your preference. See the Montigo web site for photographs and ideas. www.montigo.com Figure 28c. Completed firestone installation.
  • Page 25: Installing The Hr34Df* Artificial River Rocks

    H*34DF Indoor Gas Fireplace Installation Installing the Artificial Rocks: The HR34DF* is supplied with (40) forty faux ceramic fibre river rocks. 2 in1 Faux Rock "B" Unpack the rocks and handle them very carefully. Shown Below: 2 in1 Faux Rock "C" Top View Top View Figure 30c.
  • Page 26 H*34DF Indoor Gas Fireplace Installation Figure 30j. Completed lower layer of ceramic Rock. Step 8. Install the first faux ceramic "E" Rocks on top of the lower level Figure 30p. Place the sixth Top faux Rock on top, behind the pilot burner faux of rocks.
  • Page 27: Section 9: Operation

    H*34DF Indoor Gas Fireplace Operation with Continuous Pilot Section 9: Start up Sequence with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: Models WARNING H34DFn HC34DFn HR34DFn H34DFL HC34DFL If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 28: Start-Up Sequence With Honeywell Electronic Ignition

    H*34DF Indoor Gas Fireplace Operation with Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: Models WARNING H34DFnE HC34DFnE H34DFLE HC34DFLE If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 29: Start-Up Sequence Sit-Ipi Gas Valve

    H*34DF Indoor Gas Fireplace Operation Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: Models HL34DFnI WARNING H34DFnI HC34DFnI HL34DFLI H34DFLI HC34DFLI HR34DFnI If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 30: Maintenance

    H*34DF Indoor Gas Fireplace Maintenance Lighting Instructions Models Hi-Lo Burner See pages 27 to 29. H34DFn HC34DFn HR34DFn General Adjustment: H34DFL HC34DFL Have the fireplace and installation inspected yearly. The „ (SIT Nova 820). inspection must include, but is not limited to, the following: The H*34DF* is equipped with an adjustable burner, allowing you to •...
  • Page 31: Troubleshooting

    H*34DF Indoor Gas Fireplace Maintenance Troubleshooting: Troubleshooting Models Models (Honeywell) (SIT Nova 820). H34DFn HC34DFn HR34DFn H34DFnE HC34DFnE H34DFL HC34DFL H34DFLE HC34DFLE The following is a troubleshooting chart of possible problems: PROBLEM CORRECTIVE aCTIOn Noisy Pilot Flame Locate pilot adjustment screw on control valve.
  • Page 32: Parts List

    H*34DF Indoor Gas Fireplace Replacement Parts H34DF HC34DF HL34DF HR34DF RGC1006 RGC1006 RGC1006 RGC1006 nG Gas Valve RGC1005 RGC1005 RGC1005 LP Gas Valve RPA020 RPA020 RPA020 RPA020 nG Pilot RPA021 RPA021 RPA021 LP Pilot RBH3401 See table below RBH3401 nG Burner...
  • Page 33: Appendix

    H*34DF Indoor Gas Fireplace Appendix appendix a: Venting Terminations a = clearance to the termination frame above grade, veranda, porch, deck, Q = clearance above a roof [24 inches (61 cm) minimum] or balcony [16 inches (41 cm) minimum] R = clearance to adjacent walls and neighboring buildings B = clearance to door, or sides and top of window, that may be opened [16 [18 inches (46 cm) minimum] inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)]...
  • Page 34: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 35: State Of Massachusetts

    H*34DF Indoor Gas Fireplace Appendix appendix C: State of Massachusetts amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to nFPa-54, Chapter 10 (1) Revise nFPa-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 36 H*34DF Indoor Gas Fireplace Notes Page 36 XG0146 - 042811...
  • Page 37 H*34DF Indoor Gas Fireplace Notes Page 37 XG0146 - 042811...
  • Page 38 H34DF Residential Gas Fireplace Ferndale, washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0146 - 042811...

This manual is also suitable for:

Hr34dfHl34dfHc34df

Table of Contents