Montigo H36PVN Installation & Maintenance Manual page 15

Power vent indoor gas fireplace
Table of Contents

Advertisement

Venting Components
The following venting components and associated Montigo part
numbers are available for the EDVWSPV58:
A - Termination
EDVRSPV58
B - Rough-in Frame
EDVRSPV58F
C - Flex Sections
PLF-1 (12" Section)
PLF-2 (24" Section)
PFL-3 (36" Section)
PFL 4 (48" Section)
PEXT-1 (12" m/f Section)
D - Rigid Sections
PXT-20 (20" Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90º Elbow
PEL-90FF (f/f 90º Elbow
PEL-90FM (f/m 90º Elbow)
PEL-45FM (f/m 90º Elbow)
F - Power Cord
EPVH10-10 foot power cord & harness
Harnesses
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness
Connection and installation of the vent components should
adhere to the following guidelines:
■ Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue.
■ Ensure the pipe ends male to female slide in a minimum
of 1 1/2" of overlap.
■ Ensure all runs are supported with a minimum of 3 supports
per 10' of venting.
■ When hanging/ supporting venting, ensure that 1" clearance
is maintained on all sides to any combustible material.
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
■ Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots.
■ Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement.
XG0649 - 180130
Installation
Installation of the EDVWSPV58 external wall mounted power vent
module.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable.
The EDVWSPV58 Power Vent dimensions:
11 1/16"
11 1/16"
9.0
5
The EPVF58 Rough-in Frame dimensions:
EPVF58 DIMS (2).pdf 1 3/7/2011 9:16:30 AM
14 1/4"
4 9/16"
H36PVN Power Vent Indoor Gas Fireplace
11 1/16"
9 3/4"
10 9/16"
14 1/16"
12 5/16"
12 1/8"
1 1/2"
8
9 11/16"
10 9/16"
5
9.0
9 11/16"
4
ISOMETRIC VIEW
Page 15