Table of Contents

Advertisement

Installation & Maintenance Manual
XW2002
XW2004
XG0213
DANGER
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage
or
even
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
death.
For
XW2006
XW2012
XW2014
H38DF-CLCR
HL38DF-CLCR
HLS38DF-CLCR
Corner Unit
Residential
Fireplace
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
NOTICE
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
supplier's instructions.
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
If you cannot reach your gas supplier,
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
call the fire department.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
020111

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF-CLCR

  • Page 1 Danger of harming radiation Environment your hands Irritant Slippery floor Watch your step Cutting High temperatures Glass hazard Danger of suffocation XW2014 XG0213 020111 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H(L)38DF-CLCR Corner Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. XW2010 Table of Contents INTRODUCTION ................3 Section 7: Removing the Door ...........18 Remove the Horizontal Access Panel: .............18 BEFORE YOU START: .
  • Page 3: Introduction

    InTRODUCTIOn Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Before You Start

    Should it be impossible to meet the venting requirements laid out in Section 3:  BEFORE YOU STaRT: Venting, please contact Montigo regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight runs of 5"/8" ...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions select a location that does not interfere with room traffic, has adequate ventilation Please review the Pre-Installation Checklist on Page 4 for general information on and offers an accessible path for Direct Vent installation. preparing for a successful installation of your fireplace.
  • Page 6: Clearances

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 2: Framing the Fireplace Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace is 48 " wide, 44 " high, 25 1/4" deep, see Figure 2. NOTICE nOTE: when constructing the framed opening, please ensure there is access to install the gas line when the unit is installed.
  • Page 7: Notes For Planning Venting

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section: 3 The Direct Vent System Montigo supplies a variety of direct venting and termination options. 3. Install the (removed) Rear flue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 8.
  • Page 8: Installing A Roof Mounted Direct Vent Termination

    H(L)38DF-CLCR Corner Gas Fireplace Installation INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION Termination This section applies to installations where the direct vent termination will 2’ min. be roof mounted. Support ring VENTING LAYOUT Support plate 32’ max. Selection of components and details of venting lay out should adhere to Obstacle the following guidelines: The maximum termination point is 32’...
  • Page 9: Venting Components

    Storm Collar  pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe connected  directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 10: Installing A Wall Mount, Direct Vent Termination

    H(L)38DF-CLCR Corner Gas Fireplace Installation (D). Installation of termination from inside structure A Termination with a MOSR Frame is installed from the inside of the structure. INSTALLING A WALL MOUNT, DIRECT VENT TERMINATION This section applies to installations where the direct vent termination will be wall mounted.
  • Page 11: Venting Layout

    Vent terminations must not be recessed in walls or siding.  All through-the–wall terminations within 58" Horizontal distance of the  fireplace must have a Montigo Heat Shield (RHS102) installed. See Section 3-3-3. All through-the-wall terminations beyond 58" Horizontal distance of the ...
  • Page 12: Wall Mounted Terminations: Rear Vent

    Unacceptable vent run within shaded area. 64” If your installation does not fall within the venting graph para- meters, please contact Montigo for Power Venting options. Figure 16. Rear Vent Venting Graph for wall mounted terminations. Page 12 XG0213 - 020111...
  • Page 13: Venting Components

    Place the springs, supplied with the pipe kit, between the outer and inner  pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe connected  directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 14: Heat Shields

    H(L)38DF-CLCR Corner Gas Fireplace Installation Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the Termination falls outside of 58" Installing a Wall Mounted RHS102 Heat shield. horizontally from the fireplace. (Figure 19b and 19c) Use the RHS102 where the termination is closer to the fireplace than 58"...
  • Page 15: Section 4: Wiring

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 4: Wiring Honeywell (Q3450) Pilot Assembly WARNING Pilot Electrical If the information in these instructions is Harness Connector not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Honeywell Gas XW2008 Control (SV9501M) Gas Control...
  • Page 16: Fuel Conversion

    To check pressures, control valves have a provision to remove a  1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an accessible  When pressure testing the fireplace, location to isolate the gas supply.
  • Page 17: Section 6: Finishing

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing Around the Fireplace nOTE: National Canadian Gas Association mantel test requirements are for fire Combustible mantels and mouldings may be safely installed over the top and on the hazard prevention to combustible materials. front of the fireplace provided that they do not project beyond shaded area shown in Figure 24.
  • Page 18: Section 7: Removing The Door

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 7: Removing the Door Removing the Front door: The H*38C* Front door is removed in a few simple steps. Follow these below to Step 5: remove the Horizontal access panel, unlatch the door buckles and, remove the door. Ensure the tool is firmly Replace in reverse order.
  • Page 19: Installing The Logset

    H(L)38DF-CLCR Corner Gas Fireplace Installation Section 8: Installing the Accessories Installing the Logset The H*38C* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log Log C stands.
  • Page 20: Installing Firestones In N.g. (Natural Gas) Fireplaces

    H(L)38DF-CLCR Corner Gas Fireplace Installation Installing Firestones in N.G. (Natural Gas) Fireplaces Installing Firestones in L.P. (Propane) Fireplaces The H*38C* is supplied with firestones. Remove the Door and trim as shown in the Propane H*38C* Fireplace is supplied with firestones. Remove the Door and trim previous Instruction.
  • Page 21: Startup Sequence

    ■ This fireplace will not operate unless the correct air movement is detected by our control system.. ■ Please consulted with your contact person at Montigo should you have any problems with your start up. XW2040 Operation...
  • Page 22: Sit Nova 820

    H(L)38DF-CLCR Corner Gas Fireplace Operation SIT Nova 820 with American Flame Electronic Ignition FOr YOur SAFeTY - reAD BeFOre LIGHTInG: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 23: Honeywell

    H(L)38DF-CLCR Corner Gas Fireplace Operation Honeywell FOr YOur SAFeTY - reAD BeFOre LIGHTInG: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 Immediately call your gas supplier from a neighbour's phone. Follow the gas This appliance has a pilot which must be lighted by hand.
  • Page 24: Robert Shaw

    H(L)38DF-CLCR Corner Gas Fireplace Operation Robert Shaw FOr YOur SAFeTY - reAD BeFOre LIGHTInG: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 This appliance has a pilot which must be lighted by hand. When lighting the ...
  • Page 25: General

    H(L)38DF-CLCR Corner Gas Fireplace Maintenance Section 10: Cleaning and Maintenance Lighting Instructions See pages 21 - 24 Hi-Lo Burner Adjustment: (SIT Nova 820). General The H*38DF* is equipped with an adjustable burner, allowing you to raise or lower  Have the fireplace and installation inspected yearly. The inspection the flames.
  • Page 26: Section 11: Replacement Parts

    H(L)38DF-CLCR Corner Gas Fireplace Maintenance Section 11: Replacement Parts MODEL# H38C* H38C*I HL38C*I RGC1006 RGC3033 RGC3033 nG Gas Valve RGC1005 RGC3034 RGC3034 LG Gas Valve RPA020 RPA033 RPA033 nG Pilot RPA021 RPA034 RPA034 LP Pilot RBH38PR01 RBH38PR19 RBHL38PR19 Burner assembly nG RBH38PR02 RBH38PR20 RBHL38PR20 Burner assembly LPG RLGS47PR...
  • Page 27: Appendix A: Power Vent Locations

    H(L)38DF-CLCR Corner Gas Fireplace Appendix Appendix A: Power Vent Locations Vertical Detail Horizontal Detail A = clearance to the termination frame above grade, veranda, porch, deck, or clearance above paved sidewalk or a paved driveway located on public † balcony [30 inches (75 cm) minimum] property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [30 inches P = clearance under veranda, porch, deck, or balcony [30 inches (75 cm) minimum...
  • Page 28: Appendix B: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 29: Appendix C: State Of Massachusetts

    H(L)38DF-CLCR Corner Gas Fireplace Appendix Appendix C: State of Massachusetts amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to nFPa-54, Chapter 10 (1) Revise nFPa-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 30 H(L)38DF-CLCR Corner Gas Fireplace notes Page 30 XG0213 - 020111...
  • Page 31 H(L)38DF-CLCR Corner Gas Fireplace notes Page 31 XG0213 - 020111...
  • Page 32 H38DF CLCR Corner Gas Fireplace Ferndale, washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0213 - 020111...

This manual is also suitable for:

Hl38df-clcrHls38df-clcr

Table of Contents