FX-10DM-E DISPLAY MODULE
3.2.2

Cautions on connection

1) 5 V power supply of the FX Series PLC
The current consumption of the 10DM is 220 mA / 5V DC.
When connecting a special extension block to the FX Series PLC base unit, consider the
total supply current of the 5V DC power supply.
If the total supply current exceeds the allowable capacity, the 10DM cannot be connected.
2) Operation of the 10DM after instantaneous power interruption
The 10DM continues its operation against instantaneous power interruption of 5 ms or less.
If long power interruption of voltage drop has occurred, the 10DM stops its operation. And
when the power is recovered, the 10DM restarts its operation automatically.
3.3

Maintenance

The 10DM is not equipped with built-in consumable parts which restrain the life time such as a
battery and backlight.
- Because the 10DM adopts the EEPROM memory, it is not equipped with a built-in battery.
- The backlight is the LED type, and free from maintenance.
Installation, Wiring and Maintenance 3
3-7