LED indicators and the system does not send the error messages to the CPU module.
Error
Code
The settings in HWCONFIG and manual
16#0107
settings are not consistent with function card
1.
The settings in HWCONFIG and manual
16#0108
settings are not consistent for function card
2.
16#0201
Incorrect parameters
16#0301
Function card 1 communication timeout
16#0302
Function card 2 communication timeout
16#0400
Invalid UD Link Group ID for function card 1
16#0401
Invalid UD Link Group ID for function card 2
16#0402
Invalid UD Link Command for function card 1
16#0403
Invalid UD Link Command for function card 1

12.3.4 Troubleshooting for the Module AS00SCM as a Remote Module

Errors from the remote modules are regarded as warnings for AS Series CPU modules. The LED indicator of the CPU
module blinks and the CPU module can still operate. Use flag SM30 to manage error presentation in the remote modules.
12.3.4.1
ERROR LED Indicators Are ON
Error codes:
Error
Code
16#1301
Hardware failure
16#1302
The function card setting is incorrect.
Description
Description
C h a p t e r 1 2 Tr o u b l e s h o o t i n g
Solution
Check the settings in HWCONFIG and manual settings
for function card 1.
Check the settings in HWCONFIG and manual settings
for function card 2.
Check the parameter in HWCONFIG. Download the
parameter again.
1.
Check if the station number and the communication
format are correctly set.
2.
Check if the connection with the function card is
working correctly.
1.
Check if the station number and the communication
format are correctly set.
2.
Check if the connection with the function card is
working correctly.
1.
Check the UD Link settings.
2.
Check the warning settings in the PLC.
1.
Check the UD Link settings.
2.
Check the warning settings in the PLC.
1.
Check the UD Link settings.
2.
Check the warning settings in the PLC.
1.
Check the UD Link settings.
2.
Check the warning settings in the PLC.
Solution
1.
Check if the module is securely installed.
2.
Change and install a new AS00SCM or contact the
factory.
1.
Check if the function card is securely installed with
the AS-FCOPM card.
2.
Change and install a new function card or contact the
factory.
3.
Check if the setting in HWCONFIG is consistent with
the function card setting.
4.
Install a new AS00SCM or contact the factory.