Option
OffsetPrtX
OffsetPrtY
64
Description
Sets the position of printing on the card in the short direction.
Range: –7 to +7 special units (each unit moves the card
about 0.085 mm.)
Default: 0 special units
If the image is not centered on the card in the short direction, contact
your service provider for assistance to change this setting.
Sets the position of printing on the card in the long direction.
BACK
Y
FRONT
Card shifting direction
Range: –15 to +15 special units (each unit moves the card
about 0.17 mm.)
Default: 0 special units
If the image is not centered on the card in the long direction, contact
your service provider for assistance to change this setting.
B=2.07mm
X
LEFT
RIGHT
A=2.15mm
R
G
B
Printing start
Using Printer Manager