E-42: Crs Press M/V 1 (Low) (Warning Lamp Flashes: 63) P1255; E-42: Crs Press M/V 1 (High) (Warning Lamp Flashes: 63) P1256; E-42: Common Rail Pressure M/V 1 (Warning Lamp Flashes: 63) P1257; E-43: Egr 1 (Warning Lamp Flashes: 67) P1267 - Mitsubishi 6M60-TL Service Manual

Table of Contents

Advertisement

TROUBLESHOOTING
E-42: CRS Press M/V 1 (Low) (warning lamp flashes: 63) P1255
Generation condition
Recoverability
Control effected by electronic control unit
Actuator test
Inspection
Electronic control unit connector
Electrical equipment
E-42: CRS Press M/V 1 (High) (warning lamp flashes: 63) P1256
Generation condition
Recoverability
Control effected by electronic control unit
Actuator test
Inspection
Electronic control unit connector
Electrical equipment
E-42: Common Rail Pressure M/V 1 (warning lamp flashes: 63) P1257
Generation condition
Recoverability
Control effected by electronic control unit
Actuator test
Inspection
Electronic control unit connector
Electrical equipment
E-43: EGR 1 (warning lamp flashes: 67) P1267
Generation condition
Recoverability
Control effected by electronic control unit
Service data
Inspection
Actuator test
Electrical equipment
E-43: EGR 1 (warning lamp flashes: 67) P1268
Generation condition
Recoverability
Control effected by electronic control unit
Service data
Inspection
Actuator test
Electrical equipment
13E-34
SCV (
suction control valve
) is short-circuited to ground, or open circuited,
or coil is broken.
System recovers (power is re-supplied to electronic control unit) if signal be-
comes normal when starter switch is turned OFF → ON.
• Main injections only enabled.
• Common rail pressure upper limit provided.
• Injection rate limited to predetermined value.
• Exhaust gas recirculation control stopped.
B9: Fuel Leak Check
12
: SCV (
suction control valve
#574: SCV (
suction control valve
SCV (
) is shorted to power supply circuit.
suction control valve
System recovers (power is re-supplied to electronic control unit) if signal be-
comes normal when starter switch is turned OFF → ON.
• Main injections only enabled.
• Common rail pressure upper limit provided.
• Injection rate limited to predetermined value.
• Exhaust gas recirculation control stopped.
B9: Fuel Leak Check
12
: SCV (
suction control valve
#574: SCV (
suction control valve
SCV (
) binds and fails to operate.
suction control valve
System recovers (power is re-supplied to electronic control unit) if signal be-
comes normal when starter switch is turned OFF → ON.
• Main injections only enabled.
• Common rail pressure upper limit provided.
• Injection rate limited to predetermined value.
• Exhaust gas recirculation control stopped.
B9: Fuel Leak Check
12
: SCV (
suction control valve
#574: SCV (
suction control valve
Exhaust gas recirculation solenoid valve (M/V-1) is shorted-circuited to ground,
or open circuited.
System recovers if signal becomes normal with starter switch in ON position.
Exhaust gas recirculation control is stopped.
1F: EGR Position
A1: EGR 1
#530: Exhaust gas recirculation solenoid valve
Exhaust gas recirculation solenoid valve (M/V-1) is shorted to power supply cir-
cuit.
System recovers if signal becomes normal with starter switch in ON position.
Exhaust gas recirculation control is stopped.
1F: EGR Position
A1: EGR 1
#530: Exhaust gas recirculation solenoid valve
)
)
) system
) system
)
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents