A Plume deflector is available to assist in over-
coming boundary nuisance issues.
Fig. 6.13
6.9

Electric connection

• Unscrew screws "M" and remove the front
panel "N" by pulling it and pushing it towards
the top so that it is freed from the top hous-
ing Fig. 6.14.
Fig. 6.14
INSTALLATION
M
N
• Identify the terminal block cover lid "O" (Fig.
6.15) and open it.
O
Fig. 6.15
Electric power supply connection
• Connect the electric power supply cable
coming from the fused spur isolation switch
to the power supply terminal block of the
boiler Fig. 6.16 keeping the same connec-
tions for the live (brown wire) and the neutral
(blue wire). External 3A fuse or fused plug
with same current rating is recommended.
• Do not connect live wires to terminals to
which the room thermostat must be con-
nected.
• Connect the earth cable (yellow/green) to
an effective earth plant.
The earth cable must be the long-
est of the electric power supply
cables.
The appliance's electric power supply cable or
wire must have a section no less than 0.75
mm
, it must be kept away from hot or sharp
2
parts and however conform to the technical
regulations in force.