Biasi Inovia 25S ERP User Manual And Installation Instructions page 60

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Inovia 25S ERP:
Table of Contents

Advertisement

C.H. flow temperature °C
K=6
K=4 K=3
80
70
60
50
40
30
20
20
15
10
5
0
External temperature °C
Fig. 8.5
If the boiler is EQUIPED with the remote con-
trol (optional) refer to Fig. 8.6.
In this case K setting must be done from the
remote control.
C.H. flow temperature °C
K=6
K=4
K=3
80
70
60
50
40
30
20
20
15
10
5
0
External temperature °C
Fig. 8.6
The K coefficients is a parameter that increas-
es or reduces the boiler flow temperature
when the outside temperature changes.
When installing the external probe it is nec-
essary to set this parameter based on the ef-
ficiency of the heating system in order to opti-
mise the flow temperature (Fig. 8.6).
E.g. In order to have a flow temperature at the
heating system of 60°C with an external tem-
perature of -5°C, set a K at 1.5 (sectioned line
in Fig. 8.6).
- 60 -
ADVANCED COMMISSIONING
K=2
K=1,5
K=0,5
-5
-10
-15
-20
-25
K=2
K=1,5
K=1
K=0,5
-5
-10
-15
-20
-25
Sequence for setting the K coefficient
• Enter in "programming mode" by sequen-
tially pressing and holding keys 13 - 16 - 17
(Fig. 8.7) for 10 seconds at the same time
until the letters P01 are displayed on the
LCD display, indicating that "parameter 01,
has been activated (Fig. 8.8).
10
11
12
13 14
Fig. 8.7
Fig. 8.8
• Scroll the various parameters using keys 16
or 17 until the letters P15 are displayed on
the LCD display, indicating that "parameter
15" (Fig. 8.9) has been activated.
Fig. 8.9
• Using keys 16 or 17 it is possible to change
the value of parameter 15 from a minimum
of 01 to a maximum of 60 based on the se-
lected bend of the K coefficient in Fig. 8.6
(the value read on the display corresponds
to K coefficients decimal values).
The writing P15 - SEt alternates on the dis-
18
17
16
15