• Scroll the various parameters using keys
16 or 17 until the letters P05 are displayed
on the LCD display, indicating that "pa-
rameter 05" (Fig. 9.5) has been activated.
Fig. 9.5
• Pressing the 10 key 5 times it is possible
to modify the value of parameter 5 (see
table).
Parameter
00
05
• By pressing key 13 (Fig. 9.4) confirmation
of the inserted value is obtained.
• Press keys 16 or 17 (Fig. 9.4) to exit with-
out changing the value.
- 68 -
GAS CONVERSION
• Exiting the "programming mode" is au-
18
17
• Calibrate the gas valve according to the
16
15
• Reposition the controls panel and re-
• Apply the label indicating the gas nature
Gas type
G20
G31
tomatic, after 15 minutes, or by cutting
power.
instructions given in the Service manual,
section Gas valve - Adjustment.
mount the front panel of the body.
and pressure value for which the appli-
ance is regulated. The self adhesive label
is contained in the transformation kit.
"Warning if during any PCB re
programming
the power supply to the boiler
you may corrupt the software
setup, ensure you wait at least
10 seconds after any re pro-
gramming before any power iso-
lation event takes place".