of each heat request.
This time can be changed by a minimum of
zero to a maximum of four minutes.
• Enter in "programming mode" by sequential-
ly pressing keys 13 - 16 - 17 (Fig. 8.14) for
10 seconds at the same time until the letters
P01 are displayed on the LCD display, in-
dicating that "parameter 01" (Fig. 8.15) has
been activated.
10
11
12
13 14
Fig. 8.14
Fig. 8.15
• Scroll the various parameters using keys 16
or 17 until the letters P11 are displayed on
the LCD display, indicating that "parameter
11" (Fig. 8.16) has been activated.
Fig. 8.16
• It is possible to modify parameter 11 by
00=0s to 99=255s using keys 16 or 17
(each increase or reduction by a unit on the
display corresponds to 2,5 seconds). Ex.
- 62 -
ADVANCED COMMISSIONING
18
17
16
15
17=42 seconds.
• The writing P11 - SEt alternates on the dis-
play (Fig. 8.17).
Fig. 8.17
• By pressing key 13 (Fig. 8.14) confirmation
of the inserted value is obtained.
• Press keys 16 or 17 (Fig. 8.14) to exit with-
out changing the value.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.
Programming using the REMOTE control
• Press button
for more than 3 seconds to
enter in
mode (Fig. 8.18).
0
21
3
1
8
6
9
1 5
1
2
Fig. 8.18
and
• Press buttons
time to enter transparent programming (Fig.
8.19).