6.9

Electric connection

• Unscrew screws "K" and remove the front
panel "L" by pulling it and pushing it to-
wards the top so that it is freed from the
top housing Fig. 6.14.
K
Fig. 6.14
• Identify the terminal block cover lid "M"
(Fig. 6.15) and open it.
INSTALLATION
M
L
Fig. 6.15
Electric power supply connection
• Connect the electric power supply ca-
ble coming from the fused spur isolation
switch to the power supply terminal block
of the boiler Fig. 6.16 keeping the same
connections for the live (brown wire) and
the neutral (blue wire). External 3A fuse
or fused plug with same current rating is
recommended.
• Connect the earth cable (yellow/green)
to an effective earth.
The appliance's electric power supply cable
or wire must have a section no less than
0.75 mm
or sharp parts and however conform to the
technical regulations in force.
The earth cable must be the
longest of the electric power
supply cables.
, it must be kept away from hot
2
- 49 -