Section 5 • Fault Codes
FAULT CODES
Tip-over hazard. When adjusting
the raised drive speed settings,
the maximum raised drive speed
must not exceed 0.6 mph / 1Km/h
or 40 feet / 45 seconds /
12.2 meters / 45 seconds. If the
machine is allowed to drive faster
than specification, the machine
could become unstable and will tip
over.
Note: Additional troubleshooting of the fault codes
may by accomplished by using the hand-held
pendant motor controller programmer (Genie part
number 128551).
Note: When using the hand-held pendant motor
controller programmer, the M1 MAX SPEED needs
to be set to 33. If needed, adjust the M1 MAX
SPEED higher or lower to achieve the maximum
raised drive speed of 0.6 mph / 1Km/h or 40 feet /
45 seconds / 12.2 meters / 45 seconds.
5 - 2
Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N
The controller status indicator light will flash a fault
code to aid in troubleshooting. This indicator light
is mounted on the tilt level sensor mounting
bracket, located behind the cover on the ground
controls side.
Fault codes are two digits. The controller status
indicator light will blink the first digit of a two digit
code, pause for 1 second, and then blink the
second digit. There will be a 2 second pause
between codes.
For example: the indicator light blinks 4
consecutive times, pauses for 1 second, and then
blinks 1 time. That would indicate Fault Code 41.