N
M
L
K
C49-10
C56-1 BK (N.O.)
C56-2 WH (COM)
PR1
COIL
5
1
9
10
11
14
16
2
3
17
20
U6A
SEPEX CONTROLLER
F1
M-
B+
F2
18
B-
SCHEMATIC
BATTERY INDICATOR LED
1. LED IS RED DURING PHASES I1 AND P (BULK CHARGE). (20% BATTERY CHARGED)
2. LED IS YELLOW DURING PHASES U AND I2. (80% BATTERY CHARGED)
3. LED IS GREEN AT THE END OF CHARGE. (100% BATTERY CHARGED)
4. LED FLASHES GREEN DURING CYCLE EQUALIZATION.
5. LED IS OFF WHEN THE CHARGER IS NOT POWERED.
6. LED FLASHES RED, INDICATES DEFECT / FAULT.
INTERLOCK RELAY (N.O.), 10A CONTACT
1. CHARGER NOT CONNECTED TO BATTERY OR MAIN SUPPLY, CONTACT OPEN.
2. CHARGER CONNECTED TO BATTERY, CONTACT CLOSED.
3. CHARGER CONNECTED TO BATTERY AND MAIN SUPPLY, CONTACT OPEN.
ES34BEAB
J
I
H
AC
BATTERY
CHARGER
87
86
CHARGER ECU
30
85
SUPPLY
BATTERY
CONTACT
NC
NC
OPEN
NC
CONNECT
CLOSED
CONNECT
CONNECT
OPEN
CONNECT
NC
OPEN
June 2011
G
F
E
AC
BATTERY
CHARGER
P42BAT OR/RD
48V DC
OUTPUT
30
CR24
86
85
87
R42BAT RD
R42BAT RD
24
23
22 21
12
11 10
9
Part No. 139378
Section 6 • Schematics

Charger Interlock Option

D
C
B
C56-1 BK (NO)
C56-2 WH (COM)
PR1 - DRIVE CONTACTOR
R42BAT OR/RD
(TOP VIEW)
PR-1
DIODE
BK
WH
R42BAT RD
20
19 18
17
16
15
14
13
8
7
6
5
4
3
2
1
SEPEX CONTROLLER
WIRING DIAGRAM
Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N
A
LED
1
CHARGER
INDICATOR
2
3
4
BATTERY
5
CONTROLLER
6
7
8
6 - 53