Installation Requirements For The Commonwealth Of Massachusetts - Jøtul GF 160 DV IPI Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

139894 GF 160 DV IPI 12/17
THIS OWNER'S MANUAL PROVIDES INFORMATION TO ENSURE
SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION.
PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND
MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING
THE APPLIANCE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS APPLIANCE MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE TECHNICIAN OR AGENCY.
Suggested Tools for Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shut-off valve -
T-Handle required in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2", 7/16" open end wrench
• Phillips head screwdriver
• Flat head screwdriver
!
INSTALLER NOTE:
Leave this manual with the homeowner and
instruct them on basic operation procedures
before leaving the premises.
It is normal for some smoke and odor to
occur during initial operation as manufacturing
materials cure under heat. Please direct the
homeowner to page 23 for further details on how
to alleviate this condition and properly cure the
paint and log set materials.
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI Gas
Specialists.
2
• 1/4" nut driver
• Gloves
• Safety glasses
• Torx T-20 screwdriver for
Fuel Conversion
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
1. If there is not one already present,
on each floor level where there are
bedroom(s), a carbon monoxide detector
and alarm shall be placed in the living
area outside the bedroom(s). The carbon
monoxide detector shall comply with
NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2005
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer's instructions. A
copy of the installation instructions must
remain with the appliance or equipment
at the completion of the installation.
4. Manual gas supply line shut-off valve
Natural Gas / 67.05%
Propane
/ 67.83%
Based on CSA P.4.1-15
Jøtul GF 160 DV IPI

Hide quick links: