11. Drop the Control Compartment. Fig. 7.6.
• Locate and loosen the two 10 mm nuts that secure
the Control Compartment sides to the firebox floor.
• Slide the Compartment forward through the keyway
slots to disengage it from the nuts.
• Carefully extend the wire harnesses and set the
compartment on the floor.
12. Regulator Conversion. Fig. 7.7.
• Using a Torx T-20 screwdriver, remove the screws from
the front of the original regulator.
• Remove the regulator components from the valve and
disconnect the motor leads from the IFC box as shown
in fig. 7.8.
• Install the LP regulator motor using the new
components included in that kit.
• Connect the motor leads to Terminal M on the IFC.
See Fig. 7.8.
13. Reinstall the Control Compartment and Utility Panel.
• Engage the Compartment keyway slots with the
firebox nuts, but do not tighten.
• Engage the Utility Panel with the lower bolts on
the rear leg and re-attach the Panel to the back of the
Control Compartment using the M6 bolts previously
removed.
• Tighten the fasteners in this order:
1. Upper Utility Panel bolts
2. Lower Utility Panel bolts
3. 10mm Control Compartment nuts
Apply
Label "A"
Here.
Figure 7.8.
Motor lead connection to IFC.
Loosen
Nut
Figure 7.6.
Drop Control Compartment to access IFC.
Figure 7.7.
Regulator
motor
removal
and
installation.
To
IFC "M"
Terminal
MS
GF 160 DV IPI 12/17
Torx
Screws
17

Hide quick links: