Alcove Installation
Maximum Alcove Depth:
Minimum Alcove Width*:
Minimum Alcove Ceiling Height
from floor:
* Alcove clearances are determined through testing in
specific construction configurations which often result in
greater clearances than an open stove installation.
Clearance to Combustible Materials
Above Stove
Minimum Mantle Height from floor: 46 3/4" (118.74 cm)
with 24" (610 mm) maximum mantle depth.
8
24" (607 mm)
32 1/2" (826 mm)
69" (1752 mm)
Minimum Ceiling or Alcove Height
175.26 cm
69”
Mantle Depth
Max.
24”
11 1/4”
286 mm
46 3/4”
118.74 cm
35 1/2”
902 mm
Figure 5.4
Alcove Clearances.
Minimum Ceiling or Alcove Height
11 1/4”
286 mm
46 3/4”
118.74 cm
35 1/2”
902 mm
Figure 5.5. Mantel and Ceiling Clearances.
Max.
Mantle Depth
24”