Jøtul GF 160 DV IPI Installation And Operation Instructions Manual page 29

Direct vent gas stove
Table of Contents

Advertisement

Remote Transmitter Controls
Temperature Indication Display
With the transmitter in the OFF position, press the
Thermostat Key and the Mode Key at the same
time. The display screen will show the current
room temperature cycling between Fahrenheit and
Celsius indicators each time the keys are pressed
simultaneously. Fig. 15.3.
Pilot Mode
With the transmitter in the OFF position, press the
transmitter Mode key - IPI is the default mode. Fig.
15.4.
Press the Up arrow to index to the CPI icon and activate
the Continuous Pilot Ignition mode. Fig. 15.5. Pressing
the Down Arrow Key will return to Intermittent Pilot
Ignition. A single "beep" will confirm reception of the
command.
NOTE: Setting the stove Pilot Mode switch to IPI will
disable remote IPI/CPI switching.
Turn on the Burner
Press the ON/OFF Key on the Transmitter.
The display will show all the active icons. At the
same time, the Receiver will activate the Pilot
Ignitor. First the pilot will ignite, followed shortly
by the burner. A single" beep" from the Receiver will
confirm reception of the command.
Turn off the Burner
Press the ON/OFF Key. The display will show only
the room temperature and icon. At the same time,
the Receiver will deactivate the call for heat and
the burner will shut down. Fig. 15.7. A single "beep"
from the Receiver will confirm reception of the
command.
Remote Burner Control
There are six flame levels available.
With the system ON, and the burner flame level
at maximum, press the Down Arrow Key once to
reduce the flame height by one step. Each time the
Down Key is pressed, the flame will step down until
the burner is finally turned off. Fig. 15.8.
The Up Arrow Key will increase the flame height
each time it is pressed. If the Up Arrow Key is
pressed while the system is on but the flame is
off, the flame will come on in the High position
as in figs. 15.8 - 15.10. A single "beep" will confirm
reception of the command.
Fig. 15.3. Room temperature readings
Fig. 15.4. IPI is the
default position.
Fig. 15.6. Burner shut-down
Fig. 15.8. Flame Level 1.
Fig. 15.10. Flame Level 6.
GF 160 DV IPI 12/17
Fig. 15.5. CPI ON.
Fig. 15.7. Burner OFF.
Fig. 15.9. Flame Level 5.