Surroundings; Control Card Performance; Control Card, Usb Serial Communication; Protection And Features - Trane TR200 Instruction Manual

Hide thumbs Also See for TR200:
Table of Contents

Advertisement

Specifications

Surroundings:

Enclosure type A
Enclosure type B1/B2
Enclosure type B3/B4
Enclosure type C1/C2
Enclosure type C3/C4
Enclosure type D1/D2/E1
Enclosure type D3/D4/E2
Enclosure type F1/F3
Enclosure type F2/F4
Enclosure kit available ≤ enclosure type D
Vibration test enclosure A, B, C
Vibration test enclosure D, E, F
Relative humidity
Aggressive environment (IEC 60068-2-43) H
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature (at 60 AVM switching mode)
- with derating
- with full output power of typical EFF2 motors (up to 90% output current)
- at full continuous FC output current
1)
For more information on derating see the Design Guide, section on Special Conditions.
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
Derating for high altitude, see section on special conditions
EMC standards, Emission
EMC standards, Immunity
See section on special conditions!

Control card performance:

Scan interval

Control card, USB serial communication:

USB standard
USB plug

Protection and Features:

Electronic thermal motor protection against overload.
Temperature monitoring of the heatsink ensures that the frequency converter trips if the temperature
reaches 95 °C ± 5°C. An overload temperature cannot be reset until the temperature of the heatsink
is below 70 °C ± 5°C (Guideline - these temperatures may vary for different power sizes, enclosures
etc.). The frequency converter has an auto derating function to avoid it's heatsink reaching 95 deg C.
The frequency converter is protected against short-circuits on motor terminals U, V, W.
If a mains phase is missing, the frequency converter trips or issues a warning (depending on the load).
Monitoring of the intermediate circuit voltage ensures that the frequency converter trips if the inter-
mediate circuit voltage is too low or too high.
The frequency converter is protected against earth faults on motor terminals U, V, W.
8-10
IP 20/Chassis, IP 21kit/Type 1, IP55/Type12, IP 66/Type12
5% - 95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation
S test
2
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
IP 21/Type 1, IP55/Type12, IP 66/12
IP 21/Type 1, IP55/Type 12, IP66/12
IP21/Type 1, IP54/Type12
IP21, 54/Type1, 12
IP21, 54/Type1, 12
IP21/NEMA 1/IP 4
on top of enclosure
X
-25 - +65/70 °C
EN 61800-3, EN 61000-6-1/2,
1.1 (Full speed)
USB type B "device" plug
BAS-SVX19C-EN
IP20/Chassis
IP20/Chassis
IP00/Chassis
1.0 g
0.7 g
class Kd
1)
max. 55° C
max. 50 ° C
1)
max. 45 ° C
1)
0 °C
- 10 °C
1000 m
3000 m
: 5 ms