5.7 H: Terminal Functions
Example 2: To have an output signal of 10 V at terminal FM when the monitored value is at 76.7%, set H4-02 to 150%.
Figure 5.74
10 V
Output Voltage
5 V
0 V
0%
Example 3: To have an output signal of 3 V at terminal FM when the monitored value is at 0%, set H4-03 to 30%.
Figure 5.75
10 V
Output Voltage
3 V
0 V
0%
n
H4-07, H4-08: Multi-Function Analog Output Terminal FM, AM Signal Level Selection
Sets the voltage output level of U parameter (monitor parameter) data to terminal FM and terminal AM using parameters
H4-07 and H4-08.
When changing the setting of these parameters make sure jumper S5 on the terminal board is set accordingly. Refer to
Terminal AM/FM Signal Selection on page 67
No.
H4-07
Multi-Function Analog Output Terminal FM Signal Level Selection
H4-08
Multi-Function Analog Output Terminal AM Signal Level Selection
Setting 0: 0 to 10 V
Setting 1: -10 V to 10 V
Setting 2: 4 to 20 mA
u H5: MEMOBUS/Modbus Serial Communication
Through the drives built in RS-422/485 port (terminals R+, R-, S+, S-), serial communication is possible using
programmable logic controllers (PLCs) or similar devices running the MEMOBUS/Modbus protocol.
The H5-
parameters are used to set up the drive for MEMOBUS/Modbus Communications.
Modbus Serial Communication on page 450
u H6: Pulse Train Input/Output
A one track pulse train signal with a maximum frequency of 32 kHz can be input to the drive at terminal RP. This pulse
train signal can be used as the frequency reference, for PID functions, or as the speed feedback signal in V/f Control.
208
H4-07, 08 = 0
Gain 150%
Bias 0%
Gain 100%
Bias 0%
Gain 50%
Bias 0%
100%
Monitor Value
Figure 5.74 Analog Output Gain and Bias Setting Example 1 and 2
H4-07, 08 = 0
Bias 30%
Gain 100%
Bias 0%
Gain 100%
100%
Monitor Value
Figure 5.75 Analog Output Gain and Bias Setting Example 3
for details on setting S5.
Name
for detailed descriptions of the H5-
Output Voltage
-100%
Output Voltage
-100%
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
H4-07, 08 = 1
15 V
Gain = 150%
Bias = 0%
10 V
Gain = 100%
Bias = 0%
5 V
Gain = 50%
Bias = 0%
100%
Monitor Value
-5 V
-10 V
-15 V
Gain = 100%
H4-07, 08 = 1
Bias = 30%
10V
Gain = 100%
Bias = 0%
3 V
100%
Monitor Value
-4 V
-10 V
Setting Range
0 to 2
0 to 2
Refer to MEMOBUS/
parameters.
YEG
Default
0
0