Input Value
Control Mode
Test signal frequency
Test signal Amplitude
Motor inertia
System response frequency
u Before Auto-Tuning the Drive
Check the items below before Auto-Tuning the drive.
n
Basic Auto-Tuning Preparations
• Auto-Tuning requires the user to input data from the motor nameplate or motor test report. Make sure this data is
available before Auto-Tuning the drive.
• For best performance, the drive input supply voltage must be at least equal to or greater than the motor rated voltage.
Note: Better performance is possible when using a motor with a base voltage that is 20 V (40 V for 400 V class models) lower than the
input supply voltage. This is particularly important when operating the motor above 90% of base speed, where high torque
precision is required.
• To cancel Auto-Tuning, press the STOP key on the digital operator.
• When using a motor contactor, make sure it is closed throughout the Auto-Tuning process.
• When using Auto-Tuning for motor 2, make sure motor 2 is connected to the drive output when performing the tuning.
Table 4.11
describes digital input and output terminal operation while Auto-Tuning is executed.
Table 4.11 Digital Input and Output Operation During Auto-Tuning
Motor Type
Rotational Auto-Tuning
Stationary Auto-Tuning 1
IM Motor
Stationary Auto-Tuning 2
Stationary Auto-Tuning for Line-to-Line Resistance
Rotational Auto-Tuning for V/f Control
PM Motor Parameter Settings
PM Stationary Auto-Tuning
PM Motor
PM Stationary Auto-Tuning for Stator Resistance
Z Pulse Offset Tuning
Back EMF Constant Tuning
Inertia Tuning
IM and PM
Motors
ASR Gain Auto-Tuning
n
Notes on Rotational Auto-Tuning
• To achieve optimal performance from Rotational Auto-Tuning, the load should be decoupled from the motor.
Rotational Auto-Tuning is best suited for applications requiring high performance over a wide speed range.
• If motor and load can not be decoupled, reduce the load so that it is no greater than 30% of the rated load. Performing
Rotational Auto-Tuning with a higher load will set motor parameters incorrectly, and can cause irregular motor
rotation.
• Ensure the motor-mounted brake is fully released if installed.
• Connected machinery should be allowed to rotate the motor.
n
Notes on Stationary Auto-Tuning
Stationary Auto-Tuning modes analyze motor characteristics by injecting current into the motor for about one minute.
WARNING! Electrical Shock Hazard. When executing stationary Auto-Tuning, the motor does not rotate, however, power is applied.
Do not touch the motor until Auto-Tuning is completed. Failure to comply may result in injury from electrical shock.
WARNING! Sudden Movement Hazard. If installed, do not release the mechanical brake during stationary Auto-Tuning. Inadvertent
brake release may cause damage to equipment or injury to personnel. Ensure that the mechanical brake release circuit is not
controlled by the drive multi-function digital outputs.
Stationary Auto-Tuning 1 and 2
• Perform these tuning methods when using a vector control mode but Rotational Auto-Tuning cannot be performed.
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Table 4.10 Auto-Tuning Input Data
Input Parameter
A1-02
T3-01
T3-02
T3-03
T3-04
Auto-Tuning Type
Unit
-
Hz
rad
kgm
2
Hz
Digital Input
Digital input functions are disabled.
4.6 Auto-Tuning
Tuning Type (T1-01 or T2-01)
8
Inertia Tuning
ASR Gain Tuning
3, 7
YES
YES
YES
N/A
Digital Output
Functions the same as during normal operation
Maintains the status at the start of Auto-Tuning
Functions the same as during normal operation
Digital output functions are disabled.
Maintains the status at the start of Auto-Tuning
Functions the same as during normal operation
Functions the same as during normal operation
9
3, 7
YES
YES
YES
YES