Control Mode Selection - YASKAWA T1000A Technical Manual

Table of Contents

Advertisement

1.2 General Description
u Control Mode Selection
Table 1.2
gives an overview of the T1000A control modes and their various features.
Motor Type
Induction Synchronous
Control Mode
Parameter Setting
Basic Description
Motor Type
Multi Motor
Motor data
unknown
High Speed
Accuracy
Type of
High Speed
Applications
Response
Zero Speed
Control
Torque Control
Operation
Torque Limit
Operation
PG Option Card
Speed Control
Range
Speed Accuracy
Control
Characteristics
Speed Response
Starting Torque 150% at 3 Hz 150% at 3 Hz
• Energy
Auto-Tuning
• Termination
Torque Limit
Torque Control
Zero Servo
Control
Speed Search
Energy-Saving
Control
Feed Forward
Application-
Control
Specific
Kinetic Energy
Buffering
Overexcitation
Deceleration
Inertia Tuning,
ASR Tuning
Overvoltage
Suppression
High Frequency
Injection
Disturb
Function
26
Table 1.2 Control Modes and their Features
Induction Motors,
Induction Motors
Motors
V/f
V/f w/PG
OLV
A1-02 = 0
A1-02 = 1
A1-02 = 2
V/f control
using motor
Open Loop
V/f control
speed
Vector control
feedback
IM
IM
IM
YES
N/A
N/A
YES
N/A
N/A
N/A
YES
YES
N/A
N/A
YES
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
YES
PG-B3 or PG-
N/A
N/A
X3
1:40
1:40
1:200
±2 to 3%
±0.03%
±0.2%
3 Hz
3 Hz
10 Hz
(approx.)
(approx.)
200% at 0.3
Hz
• Energy
• Rotational
Saving
Saving
• Stationary
Tuning
Tuning
• Termination
• Termination
resistor
resistor
resistor
N/A
N/A
YES
N/A
N/A
N/A
N/A
N/A
N/A
YES
YES
YES
YES
YES
YES
N/A
N/A
N/A
YES
YES
YES
YES
YES
YES
N/A
N/A
N/A
YES
YES
YES
N/A
N/A
N/A
YES
N/A
N/A
Permanent Magnet Motors
CLV
OLV/PM
AOLV/PM
A1-02 = 3
A1-02 = 5
A1-02 = 6
Open Loop
Open Loop
Closed Loop
Vector control
Vector control
Vector control
for IPM
for PM motors
motors
IM
PM
IPM
N/A
N/A
N/A
N/A
N/A
N/A
YES
YES
YES
YES
N/A
YES
YES
N/A
YES
YES
N/A
YES
YES
N/A
N/A
PG-B3 or PG-
N/A
N/A
X3
1:1500
1:20
1:100
±0.02%
±0.2%
±0.2%
50 Hz
10 Hz
10 Hz
200% at 0
100% at 5%
200% at
r/min
speed
0 r/min
• Rotational
• Stationary
• Stationary
• Stationary
• Termination
• Termination
• Termination
resistor
resistor
resistor
• ASR
• Inertia
YES
N/A
YES
YES
N/A
N/A
YES
N/A
N/A
YES
YES
YES (IPM
YES
N/A
motors only)
YES
N/A
N/A
YES
YES
YES
YES
N/A
N/A
YES
N/A
N/A
YES
YES
YES
YES (IPM
N/A
N/A
motors only)
N/A
N/A
N/A
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Comments
CLV/PM
Default Setting is Open Loop Vector
A1-02 = 7
Control.
Closed Loop
Vector control
for PM motors
PM
N/A
N/A
YES
YES
YES
YES
YES
PG-X3
May fluctuate with characteristics and
1:1500
motor temperature.
Speed deviation when operating at
±0.02%
constant speed. May fluctuate with
characteristics and motor temperature.
Max. frequency of a speed reference signal
50 Hz
that the drive can follow. May fluctuate
with characteristics and motor temperature.
May fluctuate with characteristics and
200% at
motor temperature.
0 r/min
Performance may differ by capacity.
• Stationary
• Termination
resistor
Automatically adjusts parameter settings
• ASR
that concern electrical characteristics of the
• Inertia
motor.
• Encoder
Offset
Sets the maximum torque for the motor to
YES
protect the load and connected machinery.
Allows direct control of motor torque for
YES
tension control and other such applications.
YES
Locks the rotor position.
Bi-directional speed detection of a coasting
YES
motor to restart it without stopping.
YES (IPM
Saves energy by always operating the
motors only)
motor at its maximum efficiency.
Improves speed accuracy when the load
YES
changes by compensating effects of the
system inertia.
Decelerates the drive to allow it to ride
YES
through a momentary power loss and
continue operation.
Provides fast deceleration without using a
N/A
braking resistor.
Provides automatic Speed Control and
YES
Feed Forward function tuning.
Prevents overvoltage by reducing
regenerative torque in application where
constant speed is not required.
Note: The drive cannot reduce
YES
regenerative torque when using the V/f
Control mode. Instead try increasing the
frequency level to avoid overvoltage in V/f
Control.
Greatly increases the speed control range
N/A
of an IPM motor.
The Disturb Function changes the
N/A
frequency reference in periodic intervals.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents